■Selectable from among 4 analog outputs.[4~20mA・1~5V・0~5V・0~10V]
■Power and I/O lines are isolated from each other to enhance noise resistance.
■Can be mounted on the base plate or via the DIN rail adapter.
    
        
            | Can be combined with sensors | Can be combined with all models of pressure sensors and load cells. | 
        
            | Sensor specification | Refer to the pages of pressure sensors and load cells. | 
        
            | Calibration of amplifier and sensor | VPMC amplifiers and pressure sensors or load cells have been calibrated as a pair. Amplifiers and sensors have been calibrated as a pair under the same serial number.
 | 
    
Specification
    
        
            | Accuracy | Refer to the page of the pressure sensor or load cell to be combined with. | 
        
            | Analog Output Response | 1msec. or less (Sensor characteristics not included) | 
        
            | Linearity | ±0.1%F.S. (Sensor characteristics not included) | 
        
            | Temperature Coefficient | ±0.02%F.S./°C (Sensor characteristics not included) | 
        
            | Use Temperature Range | 0~50°C | 
        
            | Use Humidity Range | 35~85%RH (No condensation) | 
        
            | Dimensions | Base plate type: 115(W)×35(H)×50(D) DIN rail type: 95(W)×40(H)×50(D)
 | 
        
            | Weight | Approx. 190g | 
        
            | Accessories | Operation manual (1 copy)(Specify English or Japanese.) Test report (1 copy)
 |