The GX3232’s input channels are sampled sequentially at a maximum aggregate rate of 300 KS/s. Sampled data is accessed via the PCI bus and a 32 K-sample FIFO buffer. Scanned channels can be set for 2, 4, 8, 16, or 32 channels per scan with the sample clock being generated by one of two internal rate generators which employ 16-bit programmable dividers. The four output channels can be clocked at rates up to 300 KS/s and like the input channels, offer programmable ranges. Each output channel includes a dedicated 16-bit D/A converter with output data being clocked from a 32 K sample FIFO buffer, which interfaces to the PCI bus. Output clocking is generated by one of two internal rate generators which employ 16-bit programmable dividers. Sync input and sync output lines are also provided for synchronizing the input and output signals to an external event. These signals are not accessible at the TS-700’s receiver interface.



Thông số kỹ thuật


ANALOG INPUTS
Input Channels 32 single-ended or 16 differential (software configurable)
16 single-ended or 8 differential (60 V input option), the remaining 16 inputs are available for low voltage measurement
Input Voltage Ranges ±10 V, ±5 V, ±2.5 V FS 
±60 V, ±30 V, ±15 V FS (60 V input option)
Input Impedence 2 MΩ, differential
1 MΩ to ground, single-ended
180 KΩ ± 20 KΩ to ground, single-ended for 60 V input option
Bias Current 80 nA (max)
Common Mode Rejection 60 dB typical, DC - 60 Hz, differential input mode.
30 dB for 60 V input option
Common Mode Range ±10 V, differential input configuration
±60 V, 60 V input option
Overvoltage Protection ±30 V with power applied, ±15 V with power removed
±70 V (60 V input option)
Full Scale DC Accuracy ±4.2 mV, 10 V range
±2.8 mV, 5 V range
±2.0 mV, 2.5 V range
±6% of range, 60 V, 30 V & 15 V ranges
Crosstalk Rejection 80 dB, DC - 10 kHz
Integral Nonlinearity ±0.003% of FSR (max)
Differential Nonlinearity ±0.0015% of FSR (max)
A TO D CONVERTER
Resolution 16 bits
Maximum Conversion Rate 300 kS/s
Channels per Scan 2, 4, 8, 16, or 32 per scan
Maximum Scan Rate 75 kS/s in multiple channel mode
150 kS/s in 2 channel mode
300 kS/s in single-channel mode
Minimum Scan Rate 400 scans per second (single-rate generator)
0.0075 scans per second (two-rate generators)
Scanning Modes Single scan, Continuous scan, Selftest, Multiple channel, Single channel, Two channel
Clock Source 24 MHz oscillator, two 16 dividers (independent or cascadable)
Memory 32 K sample FIFO
ANALOG OUTPUT CHANNELS
Configuration Four single-ended
Output Range ±10 V, ±5 V, ±2.5 V FS (software configurable)
Output Impedence 1 Ω (max)
Output Current ±3 mA (max)
Full Scale DC Accuracy ±3.0 mV, 10 V range
±2.2 mV, 5 V range
±1.7 mV, 2.5 V range 
(no load)
Settling Time 8 µs to on LSB, typical with 50% full scale step
Integral Nonlinearity ±0.004% of FSR (max)
Differential Nonlinearity ±0.0015% pf FSR (max)