Explosion Proof
|
MOS |
IR
|
|
H2 PPM
Hydrogen
|
CO2
Carbon Dioxide
|
CH4
Methane
|
HC
Hydrocarbons
|
Part # |
65-2442RK-1000
65-2442RK-2000
|
65-2396RK-02
65-2396RK-03
65-2396RK-05
65-2396RK-10 |
65-2394RK-CH4 |
65-2394RK-HC |
Sensor |
Metal oxide
semiconductor |
Infrared |
Measuring Range |
0-1000 ppm
0-2000 ppm |
0 - 5000 ppm
0 - 5% Vol.
0 - 50% Vol.
0 - 100% Vol. |
0-100% LEL |
Lower Detectable Limit (LDL) |
2% of full scale |
Max Current Draw (24VDC) |
200 mA (power wires) 25 mA (signal wires) 3 wires |
60 mA (power wires) 25 mA (signal wires) 3 wires |
Response Time
(T-90) |
45 Seconds |
30 Seconds |
Accuracy |
± 10% of
reading or
± 5% of full scale |
± 5% of reading or
± 2% of full scale |
Life
Expectancy |
5 years plus with normal service |
5 years plus with normal service |
Operating Environment
|
Location |
Indoor or outdoor. Explosion proof for Class I, Div. 1, Groups B, C, and D. |
Temperature |
-40°F to 167°F
-40°C to 75°C |
-4°F to 122°F -20°C to 50°C |
Humidity |
0 - 99% RH, non condensing |
Housing |
Housing J Box |
Cast aluminum explosion proof, optional stainless steel J-box available |
Sensor |
Stainless steel explosion proof |
Controls
|
Zero |
Sets transmitter output to 4 mA with zero output from sensor |
Span |
Sets transmitter output to proper level when span gas is applied |
Output |
4 - 20 mA signal |
Operating Voltage |
19 VDC to 30 VDC |
11 VDC to 30 VDC |
Approvals |
UL |
C UL US |
Controllers |
Compatible with the following controllers: Beacon 110, Beacon 200, Beacon 410, and 800, also PLC and DCS systems |
Warranty |
One year materials and workmanship |