Physical
|
|
Dimensions |
Height: 8.5" 216 mm
Width 7.0" 178 mm
Depth 4.3" 109 mm |
Enclosure |
Wall mounting grey polycarbonate with hinged cover. |
Conduit
Connection
|
3/4" NPT conduit hubs, 2 provided.
1 for sensor wiring
1 for power & relay wiring |
Wiring
Termination
|
Screw type terminal block 14 gauge max. |
Power
|
Universal 115 VAC & 220 VAC, or 24 VDC nominal, battery backup option available |
Controls
|
3 internal push buttons for setup, programming, and calibration. 1 external push button for alarm reset |
|
|
Environmental
|
|
Operating Temp |
-4°F to 122°F (-20°C to 50°C) |
Storage Temp |
-4°F to 158°F (-20°C to 70°C) |
Relative
Humidity |
0 - 100% RH
|
Enclosure
Rating |
NEMA-4X enclosure, waterproof, chemical, and weather resistant. |
|
|
Inputs
|
|
Direct Wired
Sensors |
LEL
Oxygen
Carbon Monoxide
Hydrogen Sulfide
Remote amp not required for less than 500 feet.
|
4-20 mA Sensors |
Accepts any 4-20 mA transmitter (24 VDC, 2 or 3 wire). A wide variety of RKI/Riken sensors are available with 4-20 mA signals. (See list of detectable gases.) Wiring distances up to 5000 feet |
Sampling Methods |
Diffusion and sample draw heads available.
|
|
|
Outputs
|
|
Relays |
3 relays - 10 amp rating (at 115 VAC), SPDT isolated contacts. 2 relays for gas alarms and 1 trouble relay. Relays fully programmable for: increasing or decreasing alarm, latching or self reset, normally energized or normally de-energized, time delay for alarm on and alarm off |
4-20 mA |
Signal output, 4-20 mA (maximum load impedance 500 ohms), per channel |
24 VDC |
24 VDC (400 mA max) output provided to operate sample drawing adapters or other accessories
|
Display |
2 x 8 Alphanumeric display with backlighting. |
Audible |
Built-in audible alarm, 94 dB, mounted on enclosure
Coded output: pulsing = gas alarm, steady = fail |
Visual |
3 LED’s on the front cover for alarm status indication, and malfunction |
|
|
Warranty
|
One year materials and workmanship |