High speed and operability 
optimum short time non-destructive measurements in total inspection

- Within one second non-destructive measurement, ideal for total inspection 
operations such as calibration and measurement in the computer is used is easy to 
just let go by applying a probe to-measured in automatically captures the measured value 
and characteristics curve (calibration curve) but this standard 70 memory 
, company name, part NO., lot NO. is registered for each channel

Yêu Cầu Giá Tốt

Thông tin sản phẩm

Features of the eddy current type film thickness meter DMC-211

Display digital measured values, read

Most of the film on the metal (oxide film on aluminum, plating, painting, such as zinc, chrome on the iron), most of the metal coating on the non-metal (the plating or the like on the plastic) in a short period of time (within 1 second) since the non-destructive measurement, ideal for total inspection.

Easy operation by the personal computer use

The personal computer use, simple operations such as calibration and measurement is. Various measurement mode is selected can screw head, the measurement of small parts and die-casting products, such as wire rod makes it easier.

Auto capture mode equipped

You capture the automatically measured values ​​only release by applying a probe to the object to be measured is in the automatic capture mode.

Characteristic curve (calibration curve) is rich in memory

Automatic selection of the characteristic curve (calibration curve) offers a basis to 70 this memory as standard.Such as special material will be able to create a new characteristic curve (calibration curve) input if there is a standard plate.

Subscribe feature of corporate information

The other party of the company name, part NO., Lot NO. You can register for each channel. 
The total number of channels: 40 channels

Equipment statistical processing function

The measurement data can be saved for each channel, you can set statistical processing the statistics item from after to the measurement data.

Unit of measurement

The unit of measurement mm, μm, mil, MI, Å. 
Unit measured value can be changed at any time and will be automatically converted.

Measurement principle

Measurement principle When the probe was passed a high-frequency current (the probe coil) is brought closer to the metal, eddy current is generated in the metal surface layer portion. This eddy current, high-frequency magnetic field strength, frequency, received conductivity of the metal, the thickness, the influence by the shape, etc., vary the penetration depth and the size. 
And eddy currents, because it flows so as to cancel a high-frequency magnetic field of the probe, the high-frequency resistance value of the probe will change. The magnitude of the high frequency resistance change, generally does not proportional to the thickness value, in light of the internal organs or user-created characteristic curve (calibration curve), in terms of the film thickness value, the computer screen to display.

Specification of the eddy current type film thickness meter DMC-211

Model (body) Damesu DMC-211 type
principle Eddy current method
Measurement mode Thickness measurement
The number of channels 40 channels
Data capacity 100,000 data
display By the computer monitor screen
Statistical processing Maximum, minimum, mean, standard deviation, histogram, setting upper and lower limit values
Power supply AC100 ~ 240V ± 10%, 50 / 60Hz 10VA (body)
weight 3.0kg
Size 280 (W) × 230 (D) × 88 (H) mm

(Note) The specifications are subject to change without notice.

Probe specification of the eddy current type film thickness meter DMC-211

1. effect range of the probe 
during the ultra-fine probe use
Fai6mm 
Fai3mm
2. The length of a code of probe 900mm
Curved surface on the possible measured by 3. guide of type
4. type of probe MP type ... flat uneven for a curved surface (standard) 
MPG type ... flat uneven for a curved surface (Guided) 
SM type ... flat uneven for a curved surface (ultra-fine) 
RP type ... concave surface, for pipe interior surface 
SR type ... small diameter pipe interior surface for 
the above-mentioned probe There are each a, B, C, 4 kinds of D by the film thickness to be measured.
5. probe guide # 180: plane measurement 
# 120: φ25 ~ 60mm convex curved surface measurement for 
# 90: φ30mm convex curved surface measurement of the following