Ultrasound electronics and equipment: |
FOERSTER ultrasound electronics, FOERSTER analysis software |
Sender / receiver test heads: |
S1E1 / S1E3 / S1E4, 5 MHz |
Test speed: |
≤ 1,000 mm/s |
Testing distance: |
1 mm (at max. 1,000 mm/s) |
Test sensitivity: |
KSR2, KSR3 |
Dead zones:
(benchmarks, depending on reflector size and depth) |
Approx. 1.5 mm, both sides
Untested edges (depending on system concept and design, deviating |
Untested edges:
(depending on system concept and design,
deviating values may occur)
|
▪ Longitudinal edges with test ≤ 5 mm for cut plates / ≤ 15 mm for uncut plates
▪ Transverse edge without top / bottom testing ≤ 80 mm
▪ Transverse edge with top / bottom testing ≤ 5 mm (only for cut plates) |
Materials: |
Low-alloyed ferrite steel |
Plate dimensions:
(benchmarks, deviating values in accordance with customer-specific requirements) |
Length 3,000 – 52,000 mm, width 900 – 5,400 mm, thickness 5 – 175 mm |
Plate temperature: |
Surface 5 – 120 °C, optionally up to 200 °C |
Plate condition: |
▪ Rough rolled surface free from contamination, oil, grease, paint, as well as loose particles and scale
▪ Preferably no warping and deformed edges (indentation and burring at the cut or residue from flame cutting)
▪ Restricted maximum tilt |