| Use power | Single-phase AC100V ± 10V 50 / 60Hz | 
        
            | Output voltage | Three-phase AC0 ~ 150 / 300V 150VA (continuous) | 
        
            | Output current | Three-phase AC0 ~ 5A 150VA (continuous) | 
        
            | Power conditioning | Batch control, phase adjustment (single-phase / three-phase switching) | 
        
            | Frequency adjustment | 50Hz / 60Hz / continuously variable * variable range 40 ~ 70Hz (0.01Hz unit) continuously variable by the rotary encoder
 | 
        
            | Power factor (phase) adjustment | Coarse / variable * coarse range +0.5 / +0.8 / 1.0 / -0.8 / -0.5 step by the switch variable
 * variable range + 0 ~ 1.0 ~ -0 (0 ~ 360 ° phase) continuously by the rotary encoder variable
 | 
        
            | Display voltmeter (V) |  | Digital power meter | 
        
            | Phase voltage | ± 0.25% rdg + 0.05% FS (resolution 0.01V) | 
        
            | Line voltage | ± 0.75% rdg + 0.1% FS (resolution 0.01V) | 
        
            | Ammeter (A) | ± 0.25% rdg + 0.05% FS (resolution 0.001A) | 
        
            | Frequency meter (Hz) | ± 0.01% rdg (resolution 0.01Hz) | 
        
            | Reactive power meter (kVAR) | More than 5% of ± 1.5% rdg FS (resolution 0.001kVAR) | 
        
            | Reactive power meter (kVARh) | ± 1.5% rdg (resolution 0.001kVARh) | 
        
            | Power-factor meter | ± 1.0% rdg (Resolution 0.01) | 
        
            | Power meter (kWh) power meter (kW)
 | Power factor ± 0.8 or more and 1.0 or less current 2% or more and 100% or less than ± 1.0% rdg of FS power factor ± 0.8 or more and 1.0 or less current 1% 2% or more less than ± 1.5% rdg of FS
 power factor of 0.5 or more 0.8 less than the advance or delay
 more than 20% to 100% ± 1.0% rdg of current FS
 power factor of 0.5 or more 0.8 less than the advance or delay of
 less than 20% ± 1.5% more than 2% of the current FS rdg
 | 
        
            | Output Protection | Voltage, if the current output of the overload condition, activate the protective function, the output will stop. At this time, the alarm lamp lights up. | 
        
            | Test items | Voltmeter, ammeter, power meter, power meter, reactive power meter, reactive power meter, power factor meter, calibration of the frequency meter | 
        
            | usage environment | Temperature / 5 ~ 40 ℃ humidity / 20% to 80% | 
        
            | External dimensions | 250 (D) × 540 (W) × 520 (H) | 
        
            | weight | About 30kg | 
        
            | accessories | Test code set (with storage bag) owner manual case cover |