Water Auto Analyer
Maker : Humas
- Wide application range : filtration plants, water treatment plants, boiler water, etc.
- Various external output signals: alarm warning, under, calibration, equipment trouble, external pump in operation, etc.
- Semi-permanent use as LED light source
- Auto start function after black out, remote control (possible)
| >>FE 4000 (Automatic iron analyzer) |
| IItems for measurement |
Total Iron |
| Measuring range |
Low density : 0.5~100ppb / High density : 0.05~5ppm |
| Precision |
±5 |
| Resolution |
Low density : 0.1ppb / high density : 0.01ppm |
| Measuring cycle |
Low density : 6 min./cycle, high density : 3 min./cycle |
| Flow rate of sample water |
200~500mL/min (250ml/min.recommended) |
| Reagent replacement cycle |
Four weeks |
| Data output |
4~20mA, RS-485 |
| External output |
Alarm, equipment trouble, under calibration,
external pump in operation, remote control |
| Power |
AC 220V, 60Hz (AC 110V Option) |
| Applicable environment |
Non-vibration, temperature : 5~40℃,
humidity : 90% at 40℃ |
| >>AL4000 (Automatic aluminum analyzer) |
| IItems for measurement |
Aluminum |
| Measuring range |
0.01 ~ 0.3ppm |
| Precision |
±10% of F.S |
| Resolution |
0.003/0.01Abs |
| Measuring cycle |
10 min. |
| Flow rate of sample water |
200~500ml/min (250ml/min.recommended) |
| Reagent replacement cycle |
Four weeks |
| Data output |
4~20mA, RS-485 |
| External output |
Alarm, equipment trouble, calibration, external
pump in operation, remote control |
| Power |
AC 220V, 60Hz (AC 110V Option) |
| Applicable environment |
Non-vibration, temperature : 5~40℃,
humidity : 90% at 40℃ |
| >>SI 4000 (Automatic silica analyzer) |
| IItems for measurement |
Silica |
| Measuring range |
1~4000ppb as SiO2 |
| Precision |
±5 |
| Resolution |
Low density : 1ppb |
| Measuring cycle |
10 min./cycle |
| Flow rate of sample water |
200~500mL/min (250ml/min.recommended) |
| Reagent replacement cycle |
Eight weeks |
| Data output |
4~20mA, RS-485 |
| External output |
Alarm, equipment trouble, calibration,
external pump in operation, remote control |
| Power |
AC 220V, 60Hz (AC 110V Option) |
| Applicable environment |
Non-vibration, temperature : 5~40℃,
humidity : 90% at 40℃ |
| >>CU 4000 (Automatic copper analyzer) |
| IItems for measurement |
Copper |
| Measuring range |
0.1 ~ 10ppm |
| Precision |
±5% of F.S |
| Resolution |
0.006/0.001Abs |
| Measuring cycle |
5 min. |
| Flow rate of sample water |
200~500mL/min (250ml/min.recommended) |
| Reagent replacement cycle |
Four weeks |
| Data output |
4~20mA, RS-485 |
| External output |
Alarm, equipment trouble, calibration,
external pump in operation, remote control |
| Power |
AC 220V, 60Hz (AC 110V Option) |
| Applicable environment |
Non-vibration, temperature : 5~40℃,
humidity : 90% at 40℃
|