- For pipes with a diameter of more than half a meter, ultrasonic flow meters have long established themselves as a reliable and convenient flow monitoring method. Measurements in several planes are a recommended method to determine the efficiency of the turbine without the need for calibration meeting the latest international standards. Fixed installed equipment form the basis for verifying the efficiency. A deterioration of efficiency can be detected right away and therefore corrections can be initiated at an early stage.
- Acoustic Paths : 1 – 8
- Accuracy : ± 0,5% with 8 paths
- Range : ± 20 m/s
- Display : 4 lines, 20 characters
- Datalogger : internal, sampling interval user selectable
- Communication : RS-232, MODBUS, Ethernet, USB
- Inputs : max. 8 x 4-20 mA
- Outputs : max. 4 x 4-20 mA, 2 x Relay, 2 x Pulse
- Power Supply : 85-264 VAC (50-60 Hz) or 12 VDC
- Battery Backup : integrated, 2 Ah
- Enclosure : Steel, wall mounted
- Dimensions : 400 x 500 x 160 mm (WxHxD)