Features
●Stable measurement by DSP (Digital Signal Processor) even with bubbly environment
●Fitting two sensor unit to one main unit
Realizes good space factor and cost effectivity by controlling two sensors in one main unit. Different chemical, different size measurement is possible.
●Good readability by VFD
VFD (Vacuum Fluorescent Display) gives very good readability in limited installation space (HLF820).
HLF820_display
●High temperature chemical resistant
All contacting surface to the measuring liquid is made by chemical resistant NEW PFA. Genuine sel-developed ceramics element realizes the use in high temperature liquid up to 200 deg C (K type).
●Detachable cable enables easy installation
Sensor cable can be detached from the sensor unit, so the installation of the sensor unit is easily done without cable. The cable length can be selected fro 5 or 7 meters. HLFS cable
●PC monitoring is possible by RS-485 communication
Model |
HLF810
|
HLF820 |
Measurement |
Time-of-flight |
Accuracy |
±1% F.S.(DIW 20 deg C) |
Data update cycle |
0.01 second
|
power source |
Voltage |
24 V DC ±10 % (21.6 - 26.4 V) |
Power |
4 W approx. |
5 W approx. |
Display |
- |
VFD (16 charactors / 2 line) |
Digital input |
Open collector (Max 35 V / 0.1 A x 2)
Selectable from integrated value reset
or 0 (zero) point adjustment input |
Output |
4-20 mA current |
2
Resolution: 12bit (RLMax. = 450Ω) |
Digital |
Open collector (Max 35 V / 0.1 A) x 2
Selectable from comparison, integrated pulse,
instantaneous frequency or error output |
Interface |
RS-485 (MODBUS protocol, RTU mode)
Up to 32 converters can be concatenated (address setting : 1- 32)
Baud rate: 9600, 19200, 38400, 57600 bps |
Case material |
ABS |
Operating temperature |
0 - 50 deg C (No condensation) |
Weight |
130 g |
230 g |
Installation |
DIN rail |
Panel mount |