| Model | AN96951(F) | AN96950(F) | AN9653(F) | 
        
            | ACW | Out voltage range:500~3000VAC,10V/step.(5000V can be modified) Voltage accuracy:±(2.5%×setting+10V) Output frequency:50/60Hz Frequency accuracy:±0.1%×setting Breakdown current range:0.100~20.00 mA(100Ma can be modified) Current accuracy:±(2.5%×reading+5 counts) | 
        
            | IR | Output voltage range:500~3000VAC,100V/step.(5000V can be modified) Voltage peak accuracy:±5%×setting Energy capatitor:Standard 0.255uH,0.047uH is optinal Front time of impulse:0.5uS Sampling frequency:50kHz~40MHz,15 adjustemnt range Test time:1~10 times continuous Ajustment:Area,differ | 
        
            | IW | Pulse voltage range:500~3000VAC,100V/step.(5000V can be modified) Voltage peak accuracy:±5%×setting Energy capatitor:Standard 0.022uH,0.047uH is optinal Front time of impulse:0.5us Sampling frequency:50kHz~40MHz,15 adjustment range Test time:1~10 times continuous Ajustemnts:Area,differ | 
        
            | DCR | ---- | Range:0.020~0.200~2.000~20.00~200.0~2000~20000Ω Accuracy:±(0.3%×reading + 3 counts) | --- | 
        
            | Power/Voltage start | --- | Voltage range: 20~300V,10V/step. Accuracy:±(0.3%×reading +0.2%×range) Current range: 0.20~2.00~20.00A Accuracy:±(0.3%×reading + 0.2%×range) Active pwer range: 1.0~99.9W~6KW Accuracy:±(0.8%×reading +0.2%×range) Frequency range:45~500Hz Accuracy:± 0.1% ×reading | Voltage range: 20~460V,10V/step. Accuracy:±(0.3%×reading +0.2% ×range) Current range: 0.05~6.00~40.00A (100Ma can be modified) Accuracy:±(0.3%×reading + 0.2% range) Active pwer range: 1.0~99.9W~18kW Accuracy:±(0.8%×reading +0.2×range) Frequency range:45~65Hz Accuracy:±0.1%×reading | 
        
            | C voltage | --- | Voltage range:60.0~600.0V Accuracy:±0.6%×reading | --- | 
        
            | Speed | --- | Range:120~99,999rpm Accuracy:±0.1%×reading+1 | --- | 
        
            | Rotation | --- | RW/RS/RI/KEEP | --- | 
        
            | PG single | --- | PG power:5V or 12V Voltage test:0.50~15.0V Accuracy:±(0.5×reading +2 counts) Frequece range:10~1000Hz Accuracy:±0.1%×reading+1 count | --- | 
        
            | Weight(without packaging) | 33Kg |