Model/Specification |
ANFS015A(F)
|
ANFS030A(F)
|
ANFS045A(F) |
ANFS060A(F) |
ANFS090A(F) |
ANFS120A(F)
|
ANFS180A(F)
|
ANFS240A(F) |
Input |
3-phase 4-wires,AC: 380V±57V,50/60Hz±3Hz |
Output Capacity |
15kVA |
30kVA |
45kVA |
60 kVA |
90 kVA |
120 kVA |
180kVA |
240KVA |
Output Frequency |
45.0~240.00Hz |
Frequency Stability |
≤0.02% |
Output Mode |
3 phaes mode, Seperated 3 phaes mode,parallel mode |
Output Current |
110V |
45.4A |
90.9A |
136.3A |
181.8A |
272.7A |
363.6A |
545.4A |
727.2A |
220V |
22.7A |
45.4A |
68.2A |
90.9A |
136.3A |
181.8A |
272.7A |
363.6A |
Outp single current |
110V |
136.3A |
272.7A |
409.1A |
545.4A |
818.2A |
1090.9A |
1636.4A |
2181.8A |
220V |
68.2A |
136.3A |
204.5A |
272.7A |
409.1A |
545.4A |
818.2A |
1090.9A |
Output 3-phase current |
110V |
45.4A |
90.9A |
136.3A |
181.8A |
272.7A |
363.6A |
545.4A |
727.2A |
220V |
22.7A |
45.4A |
68.2A |
90.9A |
136.3A |
181.8A |
272.7A |
363.6A |
Accuracy |
Voltage |
Resolution:0.1V
Accuracy:0.2%×reading+0.2%×F.S. (45Hz—65Hz)
|
Current |
Resolution:0.1A/1A
Accuracy:0.3%×reading+0.3%×rated output |
Frequency |
Resolution:0.1Hz Accuracy:0.05% |
Power |
Resolution: 0.1kW / 0.01kW / 0.001kW
Accuracy: 0.45%×reading+0.45%×F.S. (45Hz—65Hz)
|
Line Regulation |
≤1% |
Load Regulation |
≤1% |
Voltage Distortion |
Linear load: THD<1.5%(110V±10%,220V±10%,45-65Hz);
|
Transient time |
20ms |
Phase retardation |
120°+2° |
Phase unbalance factor |
≤1% |
Crest factor |
1.41±0.1 |
Modulating voltage range |
≤3V |
Over Power |
105%≤Output<110% the output will be stopped within 15 Sec.
110%≤Output<210% the output will be stopped within 5 Sec.
200%≤Output<300% the output will be stopped within 2 Sec.
300%≤Output the output will be stopped immediately |
Protection Mode |
IGBT hot、IGBT OverCurrent、Transformer hot、Input Lack Voltage、Input Over Voltage、Output Lack Voltage、Output Over Voltage、Output Over Current、Output Over Power、Lack Output Phase |
Voltage Drop Compensation |
0.000~0.500Ω |
Softstart Time |
0.0~99.9S |
Efficiency |
>86% |
Shortcut Group |
7 groups |
Online Voltage Adjustment |
The output voltage and frequency(45-65Hz) can be adjusted online under running status. |
Communication/
Remote Control |
Communication:RS232(Standard)、RS485(Options)、GPIB(Options)、Ethernet(Options)
Remote Control:Analog Control(Options) |
Environment |
Temperature:0~40℃ Humidity:20~90%RH |
Dimension W×H×D(mm) |
600*1130*1018 |
700*1330*1218 |
800*1730*1418 |
Weight(kg) |
280 |
330 |
470 |
590 |
780 |
1030 |
1320 |
149 |