| Input channels | R&S®RTO1002/R&S®RTO1012/ R&S®RTO1022 | 2 | 
            
                |  | R&S®RTO1004/R&S®RTO1014/ R&S®RTO1024/R&S®RTO1044 | 4 | 
            
                | Bandwidth (–3 dB) at 50 Ω
 | R&S®RTO1002 and R&S®RTO1004 | 600 MHz | 
            
                |  | R&S®RTO1012 and R&S®RTO1014 | 1 GHz | 
            
                |  | R&S®RTO1022 and R&S®RTO1024 | 2 GHz | 
            
                |  | R&S®RTO1044 | 4 GHz | 
            
                | Rise time (calculated) | R&S®RTO1002 and R&S®RTO1004 | 583 ps | 
            
                |  | R&S®RTO1012 and R&S®RTO1014 | 300 ps | 
            
                |  | R&S®RTO1022 and R&S®RTO1024 | 175 ps | 
            
                |  | R&S®RTO1044 | 100 ps | 
            
                | Input impedance |  | 50 Ω ±1.5 % 1 MΩ ±1 % with15 pF (meas)
 | 
            
                | Input sensitivity | max. bandwidth in all ranges | 50 Ω: 1 mV/div to 1 V/Div 1MΩ: 1 mV/div to 10 V/Div
 | 
            
                | Effective number of bits (ENOB) of the A/D converter | full-scale sine, frequency < –3 dB bandwidth | > 7 bit (meas) | 
            
                | Acquisition system | 
            
                | Max. sampling rate (realtime) |  | 10 Gsample/s per channel | 
            
                |  | R&S®RTO1044 | 10 Gsample/s on each channel 20 Gsample/s with two active channels
 | 
            
                | Memory depth | standard configuration, per channel/1 channel active | R&S®RTO: 2-channel-model: 20 /40 Msample R&S®RTO: 4-channel-model 20 /80 Msample
 | 
            
                |  | max. upgrade (R&S®RTO-B102 option), per channel/1 channel active
 | R&S®RTO: 2-channel-model: 100 /200 Msample R&S®RTO: 4-channel-model: 100 /400 Msample
 | 
            
                | Max. acquisition rate | continuous aquisition and display, 10 Gsample/s, 1 ksample
 | 1 000 000 waveforms/s | 
            
                |  | ultra-segmented-mode | < 200 ns blind time | 
            
                | Decimation modes | any combination of decimation mode and waveform arithmetics on up to 3 waveforms per channel | Sample, Peak Detect, High Resolution, Root Mean Square
 | 
            
                | Waveform arithmetics |  | Off, Envelope, Average | 
            
                | Interpolation modes |  | Linear, Sin(x)/x, Sample&Hold | 
            
                | Horizontal system | 
            
                | Time base range |  | 25 ps/div to 50 s/div | 
            
                | Time base accuracy | after delivery/calibration | 2.5 ppm | 
            
                |  | after delivery/calibration (R&S®RTO-B4 option)
 | 0.02 ppm | 
            
                | Channel deskew |  | ±100 ns (realtime deskew, channel-to-channel trigger - e.g. State - detect deskew) | 
            
                | Trigger system | 
            
                | Trigger types |  | Edge, Glitch, Width, Runt, Window, Time-out, Interval, Slew Rate, Data2Clock, Pattern, State, Serial Pattern, I²C, SPI, optional: UART/RS-232, LIN, CAN, FlexRay
 | 
            
                | Sensitivity | definition of trigger hysteresis | can be set autimatically or manually from 0.1 div to 5 div
 | 
            
                | Min. detectable glitch |  | 100 ps | 
            
                |  | R&S®RTO1044 | 50 ps | 
            
                | Coupling modes |  | same as selected channel, optional RF suppression with selectable cutoff frequency from 100 kHz to 50 % of analog bandwidth | 
            
                | Waveform maths | 
            
                | Algebraic categories |  | mathematics, logical operations, comparison, frequency domain, digital filter | 
            
                | Hardware-accelerated mathematics
 | +, -, *, 1/x, |x|, derivative, log10, ln, log2, scaling, FIR, FFT magnitude
 | 
            
                | Analysis and measurement functions | 
            
                | Hardware-accelerated analysis |  | spectrum, histogram, mask test, cursor | 
            
                | Hardware-accelerated measurements |  | amplitude measurements, time measurements | 
            
                | General data | 
            
                | Dimensions | W x H x D | 427 mm x 249 mm x 204 mm (16.81 in x 9.8 in x 8.03 in)
 | 
            
                | Weight | R&S®RTO1024 | 9.6 kg (21.16 lb) | 
            
                | Display |  | 10.4" LC TFT color touch screen, 1024 x 768 pixels (XGA)
 | 
            
                | Connectivity |  | 1 Gbit/s LAN, 4 x USB 2.0, GPIB (optional), DVI for external monitor, external trigger |