Oxygen / Nitrogen / Hydrogen Analyzer ELEMENTRAC ONH-p Eltra

Mã sản phẩm: ONH-p |
Thương hiệu: Eltra

Giá bán: Liên hệ

The ELEMENTRAC ONH-p determines oxygen, nitrogen and hydrogen in inorganic samples by inert gas fusion in an impulse furnace with temperatures in excess of 3.000 °C.

The ELEMENTRAC ONH-p guarantees precise and fast sample analysis. The analyzer covers a wide range of applications such as metal, ceramics and other inorganic materials.


Yêu Cầu Giá Tốt

Thông tin sản phẩm

Application Examples


alloys, cast iron, ceramics, copper, refractory metals, steel, ...


Product Advantages


  • simultaneous oxygen/nitrogen or oxygen/hydrogen determination with inert gas fusion technique
  • NEW: closed gas management and optimized gas circulation for sensitive ONH determination
  • NEW: use of cost efficient argon as carrier gas possible
  • NEW: powerful catalyst furnace for precise oxygen measurement
  • NEW: gas flow system with electronic gas flow control and new leakage test
  • NEW: water-cooled sample port system for effective removal of atmospheric gases
  • flexible configurations and measuring ranges for O, N and H
  • high sensitivity IR and TC cells with low detection limits
  • short analysis time
  • powerful 8,5 kW* impulse furnace for temperatures in excess of 3,000 °C
  • economic analysis of grains without capsules
  • NEW: chemicals and tubes are hidden behind a door (removable)
  • NEW: powerful software (supporting data and application export, comment fields, and many more)
  • single and multipoint calibration (linear regression)
  • NEW: cooling via tap water or heat exchanger or chiller
  • New design allows operation in production control and laboratory


Features


Measured elements hydrogen, nitrogen, oxygen
Samples inorganic
Furnace alignment vertical
Sample carrier graphite crucibles
Field of application ceramics, engineering / electronics, steel / metallurgy
Furnace electrode impulse furnace (max. 8,5 KW*), temperatures in excess of 3,000 °C
Detection method solid state infrared absorption for oxygen thermal conductivity for nitrogen and hydrogen
Typical analysis time 120 - 180 s
Chemicals required copper oxide, magnesium perchlorate, Schuetze reagents, sodium hydroxide
Gas required compressed air, helium 99.995 % pure, nitrogen 99.995% pure, argon 99.995% pure (if required), all gases with (2 - 4 bar / 30 - 60 psi)
Power requirements 3~ 400 V, 50/60 Hz, max. 8,500 W
Dimensions (W x H x D) 57 x 77 x 63 cm
Weight ~ 161 kg
Required equipment balance (resolution 0.0001g), monitor, PC
Optional accessories carrier gas purification, external chiller, gas calibration unit
- * limited to 6.8 kw in application settings