Model
|
AN96951(F)
|
AN96950(F)
|
AN9653(F)
|
ACW
|
Out voltage range:500~3000VAC,10V/step.(5000V can be modified)
Voltage accuracy:±(2.5%×setting+10V) Output frequency:50/60Hz
Frequency accuracy:±0.1%×setting
Breakdown current range:0.100~20.00 mA(100Ma can be modified)
Current accuracy:±(2.5%×reading+5 counts)
|
IR
|
Output voltage range:500~3000VAC,100V/step.(5000V can be modified)
Voltage peak accuracy:±5%×setting
Energy capatitor:Standard 0.255uH,0.047uH is optinal
Front time of impulse:0.5uS
Sampling frequency:50kHz~40MHz,15 adjustemnt range
Test time:1~10 times continuous
Ajustment:Area,differ
|
IW
|
Pulse voltage range:500~3000VAC,100V/step.(5000V can be modified)
Voltage peak accuracy:±5%×setting
Energy capatitor:Standard 0.022uH,0.047uH is optinal
Front time of impulse:0.5us
Sampling frequency:50kHz~40MHz,15 adjustment range
Test time:1~10 times continuous
Ajustemnts:Area,differ
|
DCR
|
----
|
Range:0.020~0.200~2.000~20.00~200.0~2000~20000Ω
Accuracy:±(0.3%×reading + 3 counts)
|
---
|
Power/Voltage start
|
---
|
Voltage range:
20~300V,10V/step.
Accuracy:±(0.3%×reading +0.2%×range)
Current range:
0.20~2.00~20.00A
Accuracy:±(0.3%×reading + 0.2%×range)
Active pwer range:
1.0~99.9W~6KW
Accuracy:±(0.8%×reading +0.2%×range)
Frequency range:45~500Hz
Accuracy:± 0.1% ×reading
|
Voltage range:
20~460V,10V/step.
Accuracy:±(0.3%×reading +0.2% ×range)
Current range:
0.05~6.00~40.00A
(100Ma can be modified)
Accuracy:±(0.3%×reading + 0.2% range)
Active pwer range:
1.0~99.9W~18kW
Accuracy:±(0.8%×reading +0.2×range)
Frequency range:45~65Hz
Accuracy:±0.1%×reading
|
C voltage
|
---
|
Voltage range:60.0~600.0V
Accuracy:±0.6%×reading
|
---
|
Speed
|
---
|
Range:120~99,999rpm
Accuracy:±0.1%×reading+1
|
---
|
Rotation
|
---
|
RW/RS/RI/KEEP
|
---
|
PG single
|
---
|
PG power:5V or 12V
Voltage test:0.50~15.0V
Accuracy:±(0.5×reading +2 counts)
Frequece range:10~1000Hz
Accuracy:±0.1%×reading+1 count
|
---
|
Weight(without packaging)
|
33Kg
|