Sensor |
Housing |
Stainless Steel 1.4571, NW 10 ... 125 mm, flange EN 1092-1 |
|
|
Inner pipe |
Ceramic |
|
|
Protection category |
IP 65 according EN 60 529/10.91 |
|
|
Environment temperature |
Sensor pipe electronic:
- 20 ... + 60 °C
Sensor pipe:
- 20 ... + 80 °C (higher temperatures as option) |
|
|
Max. working pressure |
16 bar, optional 25 bar |
|
|
Working frequency |
100 kHz |
|
|
Weight |
Depending on the nominal diameter |
|
|
Velocity range |
1 ... 10 m/s |
|
|
Accuracy |
± 2 ... 5 % in the calibrated range range |
|
|
Dimension |
NW + 90 mm, L 500 mm |
|
|
|
|
|
Transmitter |
Power supply |
110 / 240 V, 50 Hz, 24 V DC |
|
|
Power consumption |
20 W / 24 VA |
|
|
Protection category |
IP 65 to EN 60 529 / 10.91 |
|
|
Operating temperature |
- 10... + 45 °C [14 ... 113 °F] |
|
|
Dimensions |
258 x 237 x 174 (W x H x D) |
|
|
Weight |
approx. 2.5 kg |
|
|
Cable glands |
3 x M 16 (4.5 - 10 mm Ø) |
|
|
Terminal clamp wire size |
0.2 - 2.5 mm² [AWG 24-14] |
|
|
Current output signal |
2 x 4 … 20 mA (0 … 20 mA), load < 500 |
|
|
Alarm output - Error output |
Relay with toggle switch - max. 250 V AC, 1 A |
|
|
Data backup |
Flash memory |
|
|
Impulse output |
Open Collector - max. 30 V, 20 mA |
|
|
RS 485 interface |
ModBus |