Sensor |
Measurement range |
From 100 g/h to 100 kg/h (depends on application) |
|
Process temperature |
Standard: 150 °C; Optional: max. 500 °C |
|
Pressure |
Max. 2 bar (Optional: up to 25 bar) |
|
Flow velocity |
Min. 2 m/sec |
|
Humidity |
60 % RH or less (non-condensing) |
|
Measurement principle |
Electrodynamics |
|
Ambient temperature |
-20 … +60 °C |
|
Sensor rod |
Material: Stainless steel, AL2O3 ceramic 99,7 %; Length: depends on application |
|
Housing material |
Aluminium |
|
Protection type |
IP 66; ATEX: Cat. 1/2 GD |
|
Electrial connection |
Connection chamber DIN M 20 |
|
Switch output measurement alarm |
Relay with switchover contact - max. 250 V/AC, 1A
Not on EX devices Cat. 1 and 2 |
|
Weight |
Ca. 1.5 kg |
|
|
|
Transmitter (field housing) |
Power supply |
110/230 V, 50 Hz (optional 24 V DC) |
|
Power consumption |
20 W / 24 VA |
|
Protection type |
IP 65 to EN 60 529/10.91 |
|
Ambient temperature |
-10 ... + 45 °C |
|
Dimensions |
258 x 237 x 174 (W x H x D) |
|
Weight |
approx. 2.5 kg |
|
Interface |
RS 485 / RS 232 C (ModBus) |
|
Cable screw connectors |
3 x M 16 (4.5 - 10 mm Ø) |
|
Connection terminals cable cross-section |
0.2 - 2.5 mm² [AWG 24-14] |
|
Current output |
4 ... 20 mA (0 ... 20 mA), load < 500 Ω |
|
Switch output measurement alarm |
Relay with switchover contact - max. 250 V AC, 1 A |
|
Data backup |
Flash memory |
|
Pulse output |
Open collector - max. 30 V, 20 mA |
|
|
|
Transmitter (DIN rail) |
Power supply |
24 V DC ± 10 % |
|
Power consumption |
20 W / 24 VA |
|
Protection type |
IP 40 to EN 60 529 |
|
Ambient temperature |
-10 ... +45 °C |
|
Dimensions |
23 x 90 x 118 (W x H x D) |
|
Weight |
Approx. 172 g |
|
Connection terminals cable cross-section |
0.2 - 2.5 mm² [AWG 24-14] |
|
Current output |
4 ... 20 mA (0 ... 20 mA), load < 500 Ω |
|
Switch output measurement alarm |
Relay with switchover contact - max. 250 V AC, 1 A |
|
Data backup |
Flash memory |
|
Pulse output |