| Principle | NOx, SO2, CO, CO2: Non dispersive infrared sensor O2: zirconia sensor or paramagnetic sensor
 
 | 
        
            | Components | 1 component: NOx, SO2, CO, CO2 2 components: NOx + SO2, NOx + CO
 3 components: NOx + SO2 + CO
 4 components: NOx + SO2 + CO + CO2
 O2 measurement can be added to above all.
 
 | 
        
            | Range | NOx: 0–50 ppm…5000 ppm SO2: 0–50 ppm…5000 ppm
 CO: 0–50 ppm…5000 ppm
 CO2: 0–10%…20%
 O2: 0–10%…25%
 | 
        
            | Repeatability | ±0.5% FS | 
        
            | Zero drift | ≤ ±1.0% FS per week Ranges below 200 ppm: ≤ ±2.0% FS per week
 In O2 measurement: ≤ ±2.0% FS per month
 | 
        
            | Span drift | ≤ ±2.0% FS per week In O2 measurement: ≤ ±2.0% FS per month
 | 
        
            | Linearity | ±1.0% FS | 
        
            | Response time | ≤ 120 s (for 90% response, from the analyzer inlet) ≤ 240 s for SO2 measurement
 | 
        
            | Output signal | • 4–20 mA DC (linear) (instantaneous values, O2-corrected instantaneous values, O2-corrected average values, O2 average)
 • Contact output
 (CO peak count and alarm, concentration alarm, under auto calibration, device error, etc.)
 
 | 
        
            | Contact input | Auto-calibration start, average reset, range switch, output hold, pump ON/OFF, etc. | 
        
            | Functions | Auto calibration, O2 correction, averaging, CO peak count and alarm, data recording | 
        
            | Operating environment | -5°C to +40°C or -10°C to +40°C, RH 90% or lower | 
        
            | Power supply voltage | 100, 110, 115, 200, 230 V AC, 50/60 Hz | 
        
            | Dimensions | 800 (H) × 1710 (W) × 615 (D) mm, for indoor use Houses six 3.4 L standard gas cylinders
 | 
        
            | Gas conditions | Temperature | Standard: ≤ 800°C Non-standard: ≤ 1000°C or 1300°C
 | 
        
            | Dust | ≤ 100 mg/Nm3 | 
        
            | Pressure | -3 to +3 kPa | 
        
            | Component | SO2: ≤ 500 ppm NOx: ≤ 1000 ppm
 CO2: ≤ 15%
 CO: ≤ 2000 ppm
 HCl: ≤ 1000 ppm
 |