| Model | VN05 | VN10 | VN20 | 
        
            | Accuracy Guaranteed Flow Rate Range (Minimum flow rate – maximum flow rate)
 | 0.05 – 1 L/min | 0.5 – 10 L/min | 3.0 – 60 L/min | 
        
            | Maximum operating flow | 3 L/min | 25 L/min | 100 L/min | 
        
            | Low flow cut-off | 0.025 L/min | 0.25 L/min | 1.5 L/min | 
        
            | Accuracy (at fluid temperature of 25°C)
 | Frequency pulse | ± 2.5 RS% (100% to 20% of maximum flow rate) ± 0.5 FS% (20% to 5% of maximum flow rate)
 | 
        
            | Unit pulse | ± 2.0 RS% (100% to 20% of maximum flow rate) ± 0.4 FS% (20% to 5% of maximum flow rate)
 | 
        
            | Piping connection (Screw size) | R1/2 | R1/2 | R1 | 
        
            | Fluid temperature range | 0 to 60℃(Non-freezing) | 
        
            | Fluid conductivity range | 50 µS/cm or higher | 
        
            | Target liquids | Conductive liquid that does not corrode the material exposed to it. | 
        
            | Operating pressure | 1 MPa or less | 
        
            | Pressure loss | 0.02 MPa or less | 
        
            | Ambient temperature and humidity | Temperature: -20°C to 60°C Humidity: 35% to 85% RH (Non-condensing)
 | 
        
            | Responsiveness | 63% response Damping time: 2 s (Standard) | 
        
            | Signal cables | Length: 0.5 m, 4-wire Red: Power + line
 White: Output 1
 Blue: Power – line (GND)
 Yellow: Output 2
 | 
        
            | LED displays | One LED display on the sensor body Green: Indicates flow rate with three scales of blinking speed.
 Red: Indicates abnormal state with the number of blinks.
 | 
        
            | Installation position | Free (Vertical piping is recommended.) | 
        
            | Output common specifications | NPN open collector Current capacity: 20: mA or less
 Voltage: 30 VDC or less
 Residual voltage when ON: 1 V or less
 | 
        
            | Output 1*2 | Frequency pulse*1 | Duty ratio | Standard 200 Hz (Can be configured by 0.1 Hz in the range between 20 and 400 Hz.)
 | 
        
            | Unit pulse | 0.001 L/P (Standard) | 0.01 L/P (Standard) | 0.1 L/P (Standard) | 
        
            | Alarm*3 | Can be selected from normal open (Standard) or normal close. Alarm contents (Power supply and voltage drops/ meter failure/ empty fluid/
 excessive flow rate/ excessive flow noise/ reverse flow)
 | 
        
            | Switch*4 | Can be selected from normal open (Standard) or normal close. Level judgment value: Can be configured by 1% in the range of 0 – 100%.
 (The maximum flow rate is converted to 100%.)
 | 
        
            | Output 2 *2 | Unit pulse | Same as output 1. | 
        
            | Alarm*3 | Same as output 1. | 
        
            | Switch*4 | Same as output 1. | 
        
            | Safety Class | IP X4(IP 64 compatible) | 
        
            | Current Consumption | 100mA or less | 
        
            | Power Source | Supply isolated power at 12 -24 VDC (±10%). Use of one unit of power supply is recommended for one unit of VN.
 | 
        
            | Exposed materials to fluids | Body: PPS resin Electrodes: SUS 316 L
 O ring: FKM
 Grounding ring: SUS 316
 |