| Chart width | 100 mm | 
        
            | Number of input channels | Continuous recording: 3 or 6 Intermittent recording: 6
 | 
        
            | Input signal | Thermocouple | 12 types | 
        
            | RTD | Pt100 | 
        
            | DC voltage | ±50 mV to ±50 V | 
        
            | DC current | converted to voltage by shunt resister | 
        
            | Measurement cycle | 3 inputs: 160 ms 6 inputs: 320 ms
 | 
        
            | Recording cycle | Continuous recording | 2 to 80 seconds | 
        
            | Intermittent recording | 30 seconds | 
        
            | Printing | Inkjet, 6-color | 
        
            | Display | Fluorescent (20-digit, 2-line) | 
        
            | Calculation function | Square root extraction, subtraction, scaling, input filter, logarithm | 
        
            | Report generation | Daily report/ totalization | 
        
            | Power supply voltage | 100–240 V AC, 50/60 Hz, or 24 V DC | 
        
            | Dimensions | 144 × 144 × 199 mm | 
        
            | Weight | Approx. 2.1 kg | 
        
            | Additional function | Light | Allowed | 
        
            | Alarm output | up to 6 | 
        
            | External control (DI) | 3 points | 
        
            | Communication | RS485 |