Parameter |
Value |
TEST MODE |
DC voltage range |
0 – 40 kV |
DC current, max |
300 mA |
Measuring uncertainty |
less than 3 % |
BURN MODE |
DC voltage range |
0 – 20 kV
|
DC current, max |
1 A |
Measuring uncertainty |
less than 3 % |
SURGE MODE |
Stages |
4; 8; 16; 32 kV |
Max. surge energy |
2400 J (at 4 kV stage);
2000 J (at 8/16/32 kV stages) |
Timer set (automatic surge mode) |
5 – 15 seconds |
Manual single surge |
yes |
Flexible voltage change during automatic operation |
yes |
Pinpointing with an acoustic receiver
|
yes |
PRELOCATION MODE |
Methods |
TDR; Arc reflection;Impulse current; Voltage coupling |
Automatic distance measuring |
yes |
Saving cable parameters into Reflectometer non‑volatile memory |
yes |
Saving reflectograms either to Reflectometer non-volatile memory or USB flash drive |
yes |
CABLE TRACING MODE |
Cable tracing using 50W audio-frequency generator with frequencies 491/ 982/ 8446 Hz with a receiver |
yes |