| Principle | Non dispersive infrared absorption method (single-beam) | 
        
            | Measurable components and ranges | CO2: 0 to 0.5%…100 vol% CO: 0 to 0.5%…100 vol%
 CH4: 0 to 1%…10 vol%
 • Up to two components
 • 2 switchable ranges
 • Maximum range ratio 1 : 5
 
 | 
        
            | Repeatability | ≤ ±0.5% FS | 
        
            | Linearity | ≤ ±1.0% FS ≤ ±2% FS when range ratio is 1 : 4 or 1 : 5
 | 
        
            | Zero drift | ≤ ±2% FS per week | 
        
            | Span drift | ≤ ±2% FS per week | 
        
            | Interference effect | ≤ ±2% FS | 
        
            | Response time | ≤ 10 s (90% response from gas inlet) | 
        
            | Analog output signal | 4–20 mA DC, 0–1 V DC, 0–100 mV DC, or 0–10 mV DC Instantaneous value output (concentration of each component)
 CP value output (option)
 | 
        
            | Display | Backlit LCD (with automatic light off function) Japanese or English (as specified)
 Instantaneous value, CP value (option), parameter setpoints
 | 
        
            | Range switchover | by key operation, automatic, or by external contact input (option)
 | 
        
            | Contact output | SPST relay contact Device error (standard), range identification signal (option)
 | 
        
            | External contact input (option) | No-voltage contact Remote range switching, remote hold of output signal
 | 
        
            | Gas inlet/outlet | Rc1/4 or NPT 1/4 | 
        
            | Purge gas flow rate | 1 L/min (as needed) | 
        
            | Finish color | Off-white (Mansell 10Y7.5/0.5 equivalent) | 
        
            | Enclosure | Steel casing, indoor use | 
        
            | Surrounding temperature/humidity | -5°C to 45°C, RH 95% or lower (no condensation) | 
        
            | Warm-up time | Approx. 30 min | 
        
            | Mounting method | Panel mount | 
        
            | Power supply voltage | 100–240 V AC, 50/60 Hz, 50 VA | 
        
            | Dimensions | H 211 x W 218 x D 257 mm | 
        
            | Weight | Approx. 5 kg | 
        
            | Calibration gas | Zero: N2 or dehumidified air Span: 90%–100% of each range
 | 
        
            | Gas conditions | Flow rate | 0.5 L/min ±0.2 L/min | 
        
            | Temperature | 0°C to 40°C | 
        
            | Pressure | ≤ 5 kPa | 
        
            | Dust | ≤ 0.3 μm | 
        
            | Mist | Unallowable | 
        
            | Moisture | Below the saturation vapor density at room temperature (Non condensing) | 
        
            | Corrosive gas | HCl ≤ 1 ppm |