General information |
|
Article number |
3.510.260.011 |
Air temperature [°C] |
|
Measuring principle |
NTC |
|
Min. measuring range [°C] |
-20 |
|
Max. measuring range [°C] |
50 |
|
Display resolution [°C] |
0.1 |
Relative humidity |
|
Measuring principle |
Capacitive |
|
Min. measuring range [% RH] |
10 |
|
Max. measuring range [% RH] |
95 |
|
Accuracy ± [% RH] |
2 |
|
Display resolution [% RH] |
0.5 |
Air pressure |
|
measuring principle |
|
|
Measuring range [hPa] |
|
|
Accuracy ± [hPa] |
|
|
Display resolution [hPa] |
|
CO₂ concentration |
|
Measuring principle |
|
|
Measuring range [ppm] |
|
|
Accuracy |
|
|
Display resolution [ppm] |
|
|
Long-term stability [ppm/a] |
|
Voltage input |
|
Min. measuring range [V] |
|
|
Max. measuring range [V] |
|
|
Accuracy ± [µV] |
|
|
Accuracy of the measured value - Voltage input ± [%] |
|
|
Resolution |
|
Current measurement |
|
Min. measuring range in two-wire operation [mA] |
|
|
Max. measuring range in two-wire operation [mA] |
|
|
Min. measuring range in three-wire operation [mA] |
|
|
Max. measuring range in three-wire operation [mA] |
|
|
Accuracy ± [µA] |
|
|
Accuracy of the measured value ± [%] |
|
|
Resolution [µA] |
|
|
Approx. output load [Ω] |
|
Thermal element K |
|
Min. measuring range [°C] |
|
|
Max. measuring range [°C] |
|
|
Accuracy Between -200 °C ... 0 °C [°C] |
|
|
Accuracy Between -200 °C ... 0 °C [°C] - Of measured value |
|
|
Accuracy Between 0 °C ... 1,200 °C [°C] |
|
|
Accuracy Accuracy between 0 °C ... 1,200 °C [°C] - Of measured value |
|
|
Resolution [°C] |
|
Thermal element J |
|
Min. measuring range [°C] |
|
|
Max. measuring range [°C] |
|
|
Accuracy -200 °C ... 0 °C [°C] |
|
|
Accuracy -200 °C ... 0 °C [°C] - Of measured value |
|
|
Accuracy Accuracy between 0 °C ... 1,200 °C [°C] |
|
|
Accuracy Accuracy between 0 °C ... 1,200 °C [°C] - Of measured value |
|
|
Resolution [°C] |
|
Thermal element S |
|
Min. measuring range [°C] |
|
|
Max. measuring range [°C] |
|
|
Accuracy Between -50 °C ... 0 °C [°C] |
|
|
Accuracy Between -50 °C ... 0 °C [°C] - Of measured value |
|
|
Accuracy 0 °C ... 1,700 °C [°C] |
|
|
Accuracy 0 °C ... 1,700 °C [°C] - Of measured value |
|
|
Resolution [°C] |
|
PT100 |
|
Min measuring range [°C] |
|
|
Max. measuring range [°C] |
|
|
Accuracy [°C] |
|
|
Accuracy of the measured value ± [%] |
|
|
Resolution [°C] |
|
Interface |
|
LAN |
|
|
USB |
|
|
Plug socket - 2x |
|
|
BNC - 2x |
|
|
RS-485 |
|
|
10-pin terminal |
|
Power supply |
|
Internal (battery) |
4 x 1.5 V, AA, operating time > 1 year (depending on sensor and configuration) |
|
External (USB) |
|
|
External (LAN, PoE model) |
|
|
Terminals for external power supply to supply the sensor |
|
Display |
|
Size [mm] |
90 x 64 |
|
LCD |
|
Memory organisation |
|
Sensing interval |
10/30 s, 1/10/12/15/30 min, 1/3/6/12/24 h |
|
Saving interval |
1/10/12/15/30 min, 1/3/6/12/24 h |
|
Memory |
16 MB, 3,200,000 measured values |
|
Data logging |
Up to 20 measurement channels in parallel |
|
Available measurement channels |
Max. 48 |
|
Available channel groups |
Max. 12 |
Housing design |
|
Plastic |
|
Dimensions |
|
Length (packaging excluded) [mm] |
166 |
|
Width (packaging excluded) [mm] |
32 |
|
Height (packaging excluded) [mm] |
78 |
Weight |
|
(packaging excluded) [kg] |
0.25 |