Fluid type
Pipe |
Fluid type |
Uniform liquid through which ultrasonic wave can propagate (deionized water, cooling water, chemical solution, tap water, etc.) |
Fluid temperature |
Detector FSSA: -20 to 100°C
Detetor FSSC: -40 to 120°C |
Pipe diameter
& material |
Detector |
Inner diameter |
Material |
FSSA (V method) |
25–50 mm |
Plastic (PVC, etc)*1
|
50–225 mm |
Plastic (PVC, etc.)*1
Metal (SS, steel, copper, alminium, etc.)*2 |
FSSC (V method) |
50–600 mm |
FSSC (Z method) |
600–1200 mm |
- *1:
- Select FSSC if the pipe material is PP or PVDF.
Allowed pipe wall thickness for FSSA is 15 mm or less if the material is PP, and 9 mm or less if the material is PVDF.
- *2:
- Select FSSC for metal pipes with coating, pipes rusting inside, pipes lined with coal tar epoxy, Teflon, mortar, or rubber, or other pipes through which the ultrasonic wave is hard to pass.
|
Performance |
Accuracy |
■ Standard version
· Plastic pipe
Detector |
Pipe inner diameter |
Velocity ≥ 2 m/s |
Velocity < 2 m/s |
FSSA |
25–50 mm |
±2.5% of rate |
±0.05 m/s |
FSSA, FSSC |
50–1200 mm |
±1.5% of rate |
±0.03 m/s |
· Metal pipe
Detector |
Pipe inner diameter |
Velocity ≥ 2 m/s |
Velocity < 2 m/s |
FSSA, FSSC |
50–1200 mm |
±2% of rate |
±0.04 m/s |
■ High-accuracy version
· Plastic or metal pipe
Detector |
Pipe inner diameter |
Velocity ≥ 2 m/s |
Velocity < 2 m/s |
FSSA |
50–225 mm |
±1.0% of rate |
±0.02 m/s |
FSSA, FSSC |
200–1200 mm |
±1.0% of rate |
±0.02 m/s |
|
Response time |
0.2 s |
Range |