TRIME®-PICO32 |
Power supply:
|
7V..24V-DC
|
Power consumption:
|
100mA @ 12V/DC during 2..3sec. of measuring
|
Moisture measuring range:
|
0..100% volumetric water content
|
Accuracy (in % volumetric water content):
|
|
conductivity range:
|
0..6dS/m
|
6..12dS/m
|
12..50dS/m
|
Moisture range 0..40%:
|
±1%
|
±2%
|
with material
specific calibration
|
Moisture range 40..70%:
|
±2%
|
±3%
|
Repeating accuracy:
|
±0.2%
|
±0.3%
|
Temperature caused drift of electronics
(full range):
|
±0.3%
|
Soil temperature measuring range:
|
-15°C...50°C
|
Soil temperature measuring accuracy:
|
±1,5°C absolute, ±0,5°C relative
|
Measurement volume:
|
0,25L ≙ 110x50mm diameter
|
Operating Temperature:
|
-15°C...50°C (extended temperature range on request)
|
Calibration:
|
Calibration for a wide range of standard soil types (in accordance with Topp (equation))
|
|
standard calibration for most soils
customizable material specific calibration
storage of up to 15 user defined calibration curves
calibration of dialectric permittivity is possible
|
Probe body:
|
waterproof sealed PVC (IP68)
|
Size:
|
155 x Ø32mm
|
Rod lenght:
|
standard: 110mm
|
Rod diameter:
|
3,5mm
|
Interfaces:
|
IMP-BUS
RS485
Analogue output: 2x 0..1V, 0(4)..20mA*
|
Options |
Interfaces |
Application |
Cable length |
Connector |
RS485 & analogue |
mobile for HD2 & PICO-BT |
1,5m |
7-pin female |
IMP-BUS |
for globeLog datalogger |
5m (special length on request) |
4-pin female |
RS485, IMP-BUS & analogue |
for analogue datalogger
Optional: E-BOX (cabel extension box)
Optional available for cable extension and current output: C-BOX (0,1V zu 0(4)..20mA converter box) |
5m (special length on request) |
10-pin end splices |
SDI-12, IMP-BUS & analogue |
for SDI-12 datalogger |
5m (special length on request) |
9-pin end splices |