| Withstanding Voltage | 
            AC 3700V, 1 minute (Between input terminal and outer case) | 
        
        
            | Storage Temperature | 
            -10℃~60℃, 80% RH max (Without condensation) | 
        
        
            | Operating Temperature | 
            0℃ to 40℃, 80% RH max. (Without condensation) | 
        
        
            | Power supply | 
            1.5V (AM-3, R6 or "AA" size)×6 | 
        
        
            | Weight | 
            Approx. 330g (Excluding batteries) | 
        
        
            | Safety standard | 
            IEC 61010-1 
            Installation categoryⅡ, 600V phase to earth. | 
        
        
            | Size | 
            170(W)×105(D)×54(H)mm | 
        
        
            | Accessories | 
            Line test lead:1 
            Earth test lead:1 
            Batteries:6 
            Test lead case:1 
            Belt:1 
            Instruction manual:1 | 
        
        
            | Display | 
            3.5 digit LCD with bar graph display, max. reading of 3200 count and annunciators | 
        
        
            | Optional accessory | 
            Test probe with remote switch | 
        
        
            | Data hold indication | 
            "DH" mark on LCD readout | 
        
        
            | Low battery indication | 
            Battery mark on LCD readout | 
        
        
            | E.M.C. standard | 
            EN 61326 | 
        
        
            | Function | 
            Insulation resistance, AC voltage | 
        
        
            | Constructional standard | 
            In accordance with IEC1557-2 or JIS C1302 (1994) | 
        
        
            | Overload protection | 
            120% of the highest nominal output voltage (10 sec.) | 
        
        
            | Battery check | 
            DC 6.3V~9.5V | 
        
        
            | Temperature characteristics(0~40℃) | 
            ±5% rdg of specified accuracy | 
        
        
            | Accuracy(DC 125V) | 
            Measuring range:0~20MΩ~OL(∞) 
            First effective range:0.02MΩ~10MΩ<±5%rdg 
            Second effective range:0.01MΩ~0.02MΩ 10MΩ~20MΩ <±10%rdg 
            Other range:100MΩ~OL(∞) :Accuracy is not Specified | 
        
        
            | Accuracy(DC 250V) | 
            Measuring range:0~50MΩ~OL(∞) 
            First effective range:0.05MΩ~20MΩ<±5%rdg 
            Second effective range:0.02MΩ~0.05MΩ 20MΩ~100MΩ <±10%rdg 
            Other range:100MΩ~OL(∞) :Accuracy is not Specified | 
        
        
            | Accuracy(DC 500V) | 
            Measuring range:0~100MΩ~OL(∞) 
            First effective range:0.1MΩ~50MΩ <±5%rdg 
            Second effective range:0.05MΩ~0.1MΩ 50MΩ~100MΩ <±10%rdg 
            Other range:100MΩ~OL(∞) :Accuracy is not Specified | 
        
        
            | Accuracy(DC 1000V) | 
            Measuring range:0~2000MΩ~OL(∞) 
            First effective range:2MΩ~1000MΩ <±5%rdg 
            Second effective range:1MΩ~2MΩ 1000MΩ~2000MΩ <±10%rdg 
            Other range:100MΩ~OL(∞) :Accuracy is not Specified | 
        
        
            | AC voltage (50/60Hz) | 
            Range/Accuracy/Input impedance/Maximum input voltage 
            AC 600V/±2.5% of full scale/Approx. 20M/AC 600V rms | 
        
        
            | Response time | 
            Less than 5 sec. (Auto ranging) | 
        
        
            | Infinity indication | 
            "OL" mark on LCD readout (Over 3200 count) |