The REG-DA regulator features a world innovation as it is equipped with a high-capacity transformer monitoring function in accordance with CEI IEC 354 (VDE 0536). This function allows the operator to call up information about the hot-spot temperature and the lifetime consumption of the transformer at any time. If required, the regulator can even activate up to six cooling levels. The oil temperature can either be recorded directly (PT 100) or via a mA input.
Apart from its basic function, every REG-DA voltage regulator can be used as a measurement transducer, recorder, statistical unit, paragramer and transformer monitor all at the same time. All important network measurement quantities are displayed in measurement transducer mode. The trends in the voltage that is to be regulated over time and a second, selectable, measurement quantity are shown in recorder mode. The statistical unit for the tap-change position offers a clear presentation of all switching operations of the tap changer. The paragramer provides a complete busbar simulation.
Interconnection of multiple voltage regulators on a network enables the mutual exchange of data between regulators over long distances.Various communications methods can be used to transfer data.This allows monitoring of multiple transformers from a centralised control centre. Parallel connection of several transfomers can be very easily implemented this way. Application-specific tasks can be implemented via freely programmable inputs and outputs. The REG-DA regulator is able to communicate with a control centre via all common scada protocols.
Characteristics:
Control of three-winding transformers
Control of phase-shifting transformers
Limit value monitoring for all measurement quantities
4 freely programmable set-point values
Programmable rated values of U and I
Parametric software WinREG for setup, programming and display as well as for PC-based archiving and evaluation of the recorder data
Simulation software REGSim™ for the simulation of any parallel operation, network and load situations
Implementation of freely programmable control tasks through
large backlit LCD (128 x 128) with all important information (tap-changer position, voltage, etc.)
Measuring functions (U, I, P, Q, S, cos ϕ, ϕ, I sin ϕ, f )
Recorder functions (2-channel chart recorder)
Statistics functions (records total number of switching operations, switching operations per tap)
Event recorder (log book)
Transformer monitoring functions incl. recording of the hot-spot temperature and lifetime consumption
14 (26) freely programmable binary inputs• 9 (21) freely programmable binary outputs
Freely programmable analogue inputs or outputs (mA)
Pt 100 direct input for RTD temp. probe (option)• Input for tap-potentiometer (200Ω...20kΩ total resistance, option)
Peripheral bus RS 485 (COM3) for additional interface modules (ANA-D, BIN-D)
ParaGramer function for the display and automation of any parallel connections with up to ten transformers
UL-certification
DOWNLOAD
User manuals
Data sheets
Brochures
Software
Firmware