Laser/Target Unit Size :
|
4.2" x 3.3" x 2.2" (107 mm x 84 mm x 50 mm) |
Housing Material: |
Impact resistant plastic |
Detector Type & Size: |
Single-axis super-linear PSD 20 mm (v) x 1 mm (h) provides 2 continuously updating alignment axes. |
Target Measurement
Resolution: |
Offset: 1.0 micron (.000039")
Angular: 0.014 mm/M (.0002"/ft.) |
Target Measurement
Accuracy: |
Offset: <0.75%
Angular: <1.5% |
Angle Sensor Range: |
+/- 3.5° |
Laser Type : |
650 nm dual-fan laser with 10mm width at 3” < 0.9mW |
Communication between
Target & Data Analyzer |
Wireless Bluetooth®
2.4 GHz radio frequency |
Angle Sensor Range: |
+/- 3.5° |
Wireless Range: |
33 feet (10 M) |
Display Platform: |
Accelerometer Resolution: 0.1°
Accuracy: +/- 1.0° |
Environmental (laser & target): |
IP 67 |
Environmental (display): |
IP -43, MIL-STD 810G rain standards |
Data Storage Capacity |
500 files |
Bracket Set |
Covers 1.5" (37.6 mm) to 6" (152.4 mm) diameter shafts. Comes with 6" (150.4 mm) posts |
Application Range |
15 feet (4.5 M) between laser and target |
Operating/Storage
Temperature |
5°F to 140°F (-15°C to 60°C) for
Laser and Target |
Operating/Storage
Temp PDA |
32°F to 104°F (0°C to 40°C)
Storage: -40°F to 158°F (-40°C to 70°C) |
Battery Life Target |
14+ hours continuous use with Bluetooth® — 15 hours with backup cable. Target can be plugged into power source during use. Battery status icon for both T-1285 Target & PDA |
Battery Life Laser |
60+ hours continuous use. Blinking LED indicates low battery status |
Battery Life PDA |
15 hours normal. |
A/C Battery Charger
Laser, Target and PDA |
110V to 220V with U.S. and European adapters |