Output Current
|
Output Voltage
|
No Load V (0%Imax)
|
0-1,20 Vac - Continuous
|
3,8 KAac (30%Imax)
|
0-0,81 Vac - Continuous
|
7,5 KAac (60%Imax)
|
0-0,42 Vac - 3 min
|
13 KAac (Imax)
|
0-0,22 Vac - 3 s
|
No Load Resolution
|
25 uVac
|
Output Frequency
|
20-400 Hz
(Power reduction applied at 50 < f > 60 Hz)
|
LOW CURRENT OUTPUT
|
(Not simultaneous with high current output)
|
Output Current
|
0-35 Aac (0 – 9 Aac continuous)
|
Voltage Output
|
0-200 Vac
|
Output Frequency
|
20-400 Hz
(Power reduction applied at 50 < f > 60 Hz)
|
Isolated output
|
Yes
|
Protection
|
fuse
|
MEASUREMENTS
|
Secondary Current
|
(for high current output)
|
Ranges
|
0-1 / 0-15 KAac
|
Resolution
|
1 Aac, 10 Aac
|
Accuracy
|
±0,2% of the value ±0,2% of the range
|
Phase angle
|
±0,25º
|
Ammeter/LowLevelVoltmeter
|
|
Amm. Ranges
|
0-0,2 /0-2/0-20 Aac
|
Amm.Resolution
|
0,1 mAac, 1 mAac, 10 mAac
|
Amm. Impedance
|
<10 mΩ
|
Volt. Ranges
|
0-30 mVac,0- 0,3 Vac, 0- 3 Vac
|
Volt. Resolution
|
0,015 mVac, 0,15 mVac, 1,5 mVac
|
Volt. Impedance
|
>3000 KΩ
|
Frequency range
|
20-400 Hz
|
Accuracy
|
±0,1% of the value ±0,1% of the range
|
Phase angle
|
±0,25º
|
Isolated input
|
Yes
|
Voltmeter
|
|
Ranges
|
0-0,2/0-2/0-20/0-300 Vac
|
Resolution
|
0,1 mVac, 1 mVac, 10 mVac, 0,15 Vac
|
Impedance
|
>120 KΩ
|
Frequency range
|
20-400 Hz
|
Accuracy
|
±0,1% of the value ±0,1% of the range
|
Phase angle
|
±0,25º
|
Isolated input
|
Yes
|
Binary Input
|
|
Type
|
Dry contact/Voltage
|
Voltage mode Levels
|
1,5 V , 15 V
|
Time resolution
|
1 ms
|
Max. Voltage
|
250 Vac
|
Isolated input
|
Yes
|
COMMUNICATIONS
|
|
2 RS-485
|
Raptor Bus connectors to control unit RAPTOR-HH and/or other units
|
2 IrDA interfaces
|
Two channels for master/slaves linking
|
GENERAL
|
|
Supply
|
230 ±10%, 50/60 Hz
|
Weight
|
35 Kg
|
Protections
|
Protected by miniature circuit breaker
|
Sec. hole diameter
|
85 mm
|
Transport
|
Wheels, folding handle, fixed handle
|