Model |
AQ7277-B01 |
AQ7277B-B01 |
AQ7277B-B02 |
Wavelength
|
1650±5 nm |
1650±5 nm |
1550±25 nm |
Distance range |
0.5, 1, 2, 5, 10,
20, 50, 100,
200, 300, 400 km
|
0.2, 0.5, 1, 2, 5,
10, 20, 30, 50,
100, 200, 300,
400, 512 km
|
Pulse width |
3, 10, 20, 50,
100, 200, 500,
1000, 2000,
5000, 10000,
20000 ns
|
3, 10, 20, 30, 50,
100, 200, 300, 500,
1000, 2000, 5000,
10000, 20000 ns
|
Sampling resolution |
5 cm, 10 cm, 20 cm,
50 cm, 1 m, 2 m,
4 m, 8 m, 16 m, 32 m
|
Min. 2 cm |
Dynamic range
|
37dB (typ.)
|
40 dB (typ.) |
50 dB (typ.) |
Event dead zone
|
0.8m (typ.)
|
0.6 m (typ.) |
0.6 m (typ.) |
Attenuation dead zone
|
12m (typ.)
|
4 m (typ.) |
4 m (typ.) |
Distance measurement
accuracy |
±1 m ± measurement
distance x 2 x 10-5 ± 1 sampling resolution
|
±0.75 m ± measurement
distance x 2 x 10-5 ± 1
sampling resolution
|
Number of sampling data |
Max. 100,000 points
|
Max. 256,000 points |
Remote control interface |
LAN
(10BASE-T/100BASE-TX),
USB1.1 (Type B)
|
LAN
(10BASE-T/100BASE-TX),
USB2.0 (Type B mini)
|
Alarm Output |
Status query,
LED drive signal
|
Status query,
LED drive signal
|
Environmental Conditions |
Operating temperature |
0 to +50 °C |
-10 to 50 °C |
Storage temperature |
-20 to +60 °C |
-20 to 60 °C |
Humidity |
85% RH or less
(no condensation)
|
0 to 90% RH
(no condensation)
|
Power requirements
|
12 VDC, 18W |
12 VDC 2.5 A or less |
Dimensions and Weight
|
280 mm (W) x 73 mm (H)
x 190 mm(D),Approx. 2 kg
|
230 mm (W) × 50 mm (H)
× 140 mm (D), Approx. 1 kg
|
Laser safety standards |
Class 1M (IEC 60825-1)
|
Class 1 (IEC 60825-1) |