RIPPLE AND NOISE |
Less than 3 mV peak-to-peak as observed on a 50 MHz bandwitdh scope. |
RECOVERY TIME AND STABILITY |
Recovery: Less than 100 µs return with regulation limits for 10% to 100 % step-change in rated load.
Stability: After 1 hr. warmup ±0.5% for 6 months at constant load, line and ambient.
|
CIRCUIT PROTECTION |
Fully protected against short circuits or overloads by foldback circuitry. |
MODULE CONNECTORS |
AMP 202516-3 (or equiv.) connectors wired to DC output busses, high quality ground and 115 VAC. |
DIMENSIONS |
Model AP-1: 8 5/8" W x 11 5/8" H x 14 3/4" D
(219x295x374 mm).
Model AP-2H: 11 1/4" W x 11 5/8" H x 14 3/4" D
(285x295x374 mm).
Model AP-3: 11 1/4" W x 11 5/8" H x 15 1/4" D
(285x295x387 mm).
|
WEIGHT |
Model AP-1: 11 lbs. net (5 kg); 17 lbs. shipping (7.7 kg).
Model AP-2H: 15 lbs. net (6.8 kg); 21 lbs. shipping (9.5 kg).
Model AP-3: 16.5 lbs. net (7.5 kg); 23 lbs. shipping (10.5 kg).
|
AMBIENT |
0°C to 50°C (32°F to 122°F), without derating. |
FINISH |
Baked vinyl paint. Body, light gray; side panels, charcoal gray. |
POWER |
115/230 V ±12%, 50/60 Hz. |