AXV28-1
|
AXV44-1.5
|
AXV62-1
|
Maximum Output Voltage
|
28kV Peak (20kV RMS)
|
44kV Peak (31kV RMS)
|
62kV Peak (44kV RMS)
|
Output Modes
|
AC Hipot (VLF) Sinusoidal and load independent. DC Hipot (Negative or Positive Polarity). Burn, Cable Fault Conditioning Mode. Sheath/Jacket Testing
|
Maximum Load Capacity, VLF
|
1µF @ 0.1 Hz, Up to 5µF at reduced frequency
|
1.5µF @ 0.1 Hz, Up to 7.5µF at reduced frequency
|
1µF @ 0.1 Hz, Up to 5µF at reduced frequency
|
VLF Test Frequencies
|
Selectable 0.1 Hz, 0.05Hz, 0.02 Hz, 0.01 Hz (Additional Frequencies available upon request)
|
Main Supply
|
120V AC or 240V, 50/60 Hz AC +/- 10% (Operating voltage must be specified at time of purchase)
|
Duty Cycle
|
Continous
|
Environmental
|
-4° F (-20° C) to 113° F (45° C) Humidity non condensing
|
Metering
|
Voltage - True RMS and/or Peak, 0.1kV ± 1%. Current – 0.1mA ± 1%
|
Computer Interface/Memory
|
USB Port – Unlimited Test Record Storage with USB Drives. No Specialized Software Required, Automatic Storage of Results
|
Dimensions H x W x D
Weight
|
49” (124 cm) x 23” (58 cm) x 25” (64 cm)
150 lbs (68 kg)
|
49” (124 cm) x 23” (58 cm) x 25” (64 cm)
177 lbs (80 kg)
|
49” (124 cm) x 26” (66 cm) x 25” (64 cm)
250 lbs (113 kg)
|