PCD 650 pH/Conductivity/ Dissolved Oxygen Meter Kit with NIST Traceable Calibration Report WD-35434-71 Oakton

Mã sản phẩm: WD-35434-71 |
Thương hiệu: Oakton

Giá bán: Liên hệ
These top-of the-line waterproof meters offer features that are typically found on much more expensive models. The IP67-rated housing allows use in dirty and wet environments without harm to the meter. Datalog up to 500 points either automatically, manually, or at timed intervals.

Yêu Cầu Giá Tốt

Thông tin sản phẩm
Features

WD-35434-71 PCD 650 pH/Conductivity/ Dissolved Oxygen Meter Kit with NIST Traceable Calibration Report
Durable waterproof and dustproof  design with IP67 rating
Push-button calibration for all  parameters
Large back-light graphic display
User-settable “calibration due” alarm
Built-in real-time clock
Store up to 500 data sets
Set point alarms
Research-grade accuracy
Electrode status indicator
Password protection
Rugged rubber boot


Model PCD 650 meters
Range pH –2.000 to 20.000 pH
Ion 0.001 to 19,900 ppm, molar, or mg/L
mV ±2000 mV
Conductivity 0 to 500.0 mS
TDS 0 to 500 ppt
Salinity 0 to 80 ppt
Resistivity 0 to 20.00 MΩ
DO 0.00 to 90.00 mg/L (ppm), 0.0 to 600.0%
Temperature –10.0 to 110.0°C (14.0 to 230.0°F), selectable
Resolution pH 0.1/0.01/0.001 pH
Ion 2 or 3 digits
mV 0.1 mV
Conductivity 0.05% full-scale
Conductivity ±0.05 % full-scale
Temperature 0.1°C (0.1°F)
Accuracy pH ±0.002 pH
Ion ±0.5% full-scale (monovalent); 1% full-scale (divalent)
mV ±0.2 mV
Conductivity 1% full-scale
DO ±0.2 mg/L; ±2%
Temperature ±0.5°C (±0.9°F)
Calibration pH Up to 6 buffer values (select from 4 sets): USA: 1.68, 4.01, 7.01, 10.01, 12.45;
NIST: 1.68, 4.01, 6.86, 9.18, 12.45; DIN: 1.09, 2.06, 4.65, 6.79, 9.23, 12.75; or custom buffers
Ion Up to 6 points
Conductivity Manual up to 5 points (1 per range); automatic up to 4 points
(84.0 µS/cm, 1413 µS/cm; 12.88 mS/cm, 111.8 mS/cm)
DO Two points; 100% and 0%
Temperature Offset 0.1°C (0.1°F) increments
General Specification
TDS factor 0.40 to 1.00
Cell constant 0.100 to 10.000
DO salinity correction Range: 0.0 to 50.0 ppt
Resolution: 0.1 ppt
DO pressure correction Range: 500 to 1499 mm Hg, 66.6 to 199.9 kPa
Resolution: 1 mm Hg, 0.1 kPa
Memory up to 500 sets with GLP date and time
Output infrared, IrDA
Real-time clock time-and-date stamp on calibration and stored data
Temperature normalization 15 or 30°C
Temperature coefficient linear or pure
Temperature compensation automatic or manual (selectable) from 0 to 100°C
Ambient operating temperature 0 to 50°C (32 to 122°F)
Power four 1.5 V AA batteries (included) or optional
universal AC adapter, up to 200 hours continuous use
Dimensions
Meter 7 1/2 "L x 3 3/4 "W x 2 1/4 "H (19 x 9.5 x 5.7 cm)
Boxed 9 1/8 "L x 9 1/8 "W x 2 3/4 "H (23 x 23 x 7 cm)
Weight
Meter 1 lb (0.5 kg)
Boxed 2. lb (0.9 kg)