Máy đo phóng xạ, bức xạ RAD-60 Personal Electronic Dosimeter, Sievert Display

Mã sản phẩm: RAD-60 |
Thương hiệu: RPD

Giá bán: Liên hệ

Máy đo phóng xạ, bức xạ

Model  : RAD-60

Hãng sản xuất  : RPD

Yêu Cầu Giá Tốt

Thông tin sản phẩm

Máy đo phóng xạ, bức xạ

Model :RAD-60

Hãng sản xuất  : RPD

RAD-60 Personal Electronic Dosimeter, Sievert Display.

The RAD-60 Personal Electronic Dosimeter is a precise and reliable instrument for ensuring the personal safety of the user. Ideally, the RAD-60 is used in everyday radiation monitoring, in stand-alone conditions. If your needs grow for a more sophisticated system, the versatile RAD-60 can also be integrated into an Access Control System. The RAD-60 can be switched into System Mode, for the purpose of tracking Personnel Dose records and generating compliance reports.

The design includes state-of-the-art technology with built in memory for retrieving dose, even during power-down. It eliminates outside interference from shock and RF. The RAD-60 is easily programmed by the user, has a digital display, and operates with a single AAA alkaline battery.

• Gamma and X-Ray Detected from 60 keV to 6 Mev.

• Individual Personal Alarming Dosimeter.

• Digital Display for Integrated Dose or Alternatively Dose Rate.

• User Selectable Alarm Levels for both Dose and Dose Rate.

With the push of a button, you can turn the unit on/off, change the digital display to read dose or dose rate, select from several dose and dose rate alarm levels, turn the chirp function on/off, reset the integrated dose, and perform battery tests. The large digital display gives instant dose or dose rate readings and the audible alarm is loud (>85dba).

Specifications
Radiation Detected:
  Gamma and X-rays
Detector Type:  Energy-Compensated Si-Diode

Measurement Range
Dose:  1 µSv - 9.99 Sv
Dose Rate:  5 µSv/h - 3 Sv/h

Calibrations:  Better than ±5 % (Cs-137, 662 keV at 2 mSc/h), Hp(10)
Energy Response:  Hp(10), 60 keV - 3 MeV, better than ±25%, up to 6 MeV, better than ±35%
Dose Rate Linearity:  Better than ±15%, up to 3 Sv/h

Audible Alarms:  Seven separate alarms, sound level typically better than 85 dBa at 30 cm
Integrated dose
Dose rate
Dose overflow
Dose rate overflow at 3 Sv/h
Low battery 1 and 2
Defect

Alarm Thresholds:  Six preset values each for integrated dose and dose rate, push button selection.
Power Supply: One AAA alkaline cell, typical life is 1800 hrs in background (dose mode)
Connectors: Infrared communication via bottom of the dosimeter

Push-Button functions:  Front panel push-button has the following functions
Change display priority (dose/dose rate)
Switch ON/OFF
Chirp ON/OFF
Reset Integrated Dose
Change Alarm Thresholds
Activate Battery Test

Temperature Range:  -20 to +50°C operational, humidity up to 90% RH, non-condensed; -20 to + 70°C storing
Dimensions: 3.06" x 2.63" x 0.86" (78 x 67 x 22 mm)
Weight: 2.82 oz (80 g) including battery

Note: The active alarm thresholds and configurations of push button functions can be changed by using ADR-1 Reader in combination with RADOS PC software.