General |
Control Module |
Slave Modules |
100 V High Voltage |
Femto Ammeter |
2 A Booster |
XM MAT 1MHz |
XM MHV100 |
XM MFA |
XM MBST 2A |
Chassis slots taken |
Single |
Single |
Single |
Double |
Measurement mode |
2 or 4 terminal |
2 or 4 terminal |
2 or 4 terminal |
2 or 4 terminal |
Sample connections from module |
Gen, VHi, VLo, I |
Gen, VHi, VLo
MAT- I |
I
MAT- Gen, VHi, VLo |
Gen, I
MAT- VHi, VLo |
Sample connection cables (1 m length) |
4 x BNC to BNC |
MAT cables |
Triax to BNC |
MAT cables |
Floating |
Yes |
Yes |
Yes |
Yes |
General Output - (Gen) |
XM MAT 1 MHz |
XM MHV100 |
XM MFA |
XM MBST 2A |
Maximum waveform generator sample rate |
64 MS/s
Interpolated/filtered |
Uses MAT |
N/A |
Uses MAT |
Maximum voltage (open circuit load) DC + peak AC
(subject to slew rate limit) |
±8 V |
±100 V |
N/A |
±8 V with MAT
±20 V with MHV |
Maximum voltage resolution |
150 μV (< 3 V)
400 μV (≥ 3 V) |
2 mV (< 37 V)
5 mV (≥ 37 V) |
N/A |
1.5 mV |
Maximum output current |
±100 mA |
±100 mA |
N/A |
±2 A |
Output impedance (nominal) |
50 Ω |
50 Ω |
N/A |
< 1 Ω |
Applied voltage error (open-circuit load) |
±0.2% setting
±800 μV (< 3 V)
/ ±2 mV (≥ 3 V) |
±0.2% setting
±12.5 mV (< 37 V)
/ ±35 mV (≥ 37 V) |
N/A |
±0.2% setting +
±10 mV (< 3 V)
/ ±25 mV (≥ 3 V) |
Voltage sweep rate |
1.6 MV/s to 1 μV/s |
10 MV/s to 1 μV/s |
N/A |
1.6 MV/s to 1 μV/s |
Recommended maximum sweep rate
(using 1 MS/s acquisition rate) |
25 kV/s |
150 kV/s |
N/A |
25 kV/s |
Minimum pulse duration |
1 μs |
Uses MAT |
N/A |
Uses MAT |
Maximum slew rate |
>10 V/μs |
>15 V/μs |
N/A |
>10 V/μs |
Voltage Measurement - (VHi/VLo) |
XM MAT 1MHz |
XM MHV100 |
XM MFA |
XM MBST 2A |
Maximum voltage |
±8 V |
±100 V |
N/A |
N / A |
Voltage ranges |
8, 3, (V)
300, 30, 3 (mV) |
100, 37.5, 3.75 (V)
375 , 37.5 (mV) |
N/A |
N / A |
Voltage measurement error |
±0.1% reading +
±0.05% range +
±100 μV |
±0.1% reading +
±0.05% range +
±100 μV |
N/A |
N / A |
Maximum time domain measurement rate |
1 MS/s |
N / A |
N/A |
N / A |
Maximum time record |
Unlimited |
N / A |
N/A |
N / A |
Current measurement - (I) |
XM MAT 1MHz |
XM MHV100 |
XM MFA |
XM MBST 2A |
Maximum current |
±100 mA |
N / A |
±100 mA |
±2 A |
Current ranges |
100 mA, 30 mA to
30 nA in decades |
N / A |
100 mA, 30 mA to
3 pA in decades |
2 A plus MAT
ranges |
Maximum resolution |
1.5 pA |
N / A |
0.15 fA |
1.5 pA (MAT) |
Current measurement error |
±0.1% reading +
±0.05% range +
±100 pA |
N / A |
±0.1%** reading +
±0.05% range +
±30 fA |
±0.1% reading +
±0.05% range +
±0.1 mA |
Auxiliary voltage inputs |
XM MAT 1MHz |
XM MHV100 |
XM MFA |
XM MBST 2A |
Number of auxiliary DC channels |
Four |
N / A |
N/A |
N / A |
Voltage ranges |
8 V, 3 V to 3 mV |
N / A |
N/A |
N / A |
Maximum resolution |
1 μV |
N / A |
N/A |
N / A |
Synchronized to VHi, VLo measurement |
Yes |
N / A |
N/A |
N / A |