Khúc xạ kế DHR 95 Schmidt Haensch
Basic specifications
Calibration |
Distilled Water |
Prism Material |
Optical Glass |
Sample Temperature |
5 - 60 Degree Celsius |
Ambient Temperature |
5 - 40 Degree Celsius |
Automatic Temperature Correction |
5 - 70 Degree Celsius for 0 - 80 Brix |
Dimensions (LxWxD) |
115 x 54 x 30 mm |
Weight |
85 Grams (without Batteries fitted) |
Power |
2xAAA Batteries |
Ratings & Compliance |
IP65 Dustproof/Water Resistant, CE, RoHS |
Range of models
DHR 95 (Standard Model) |
Measuring scales: Sugar % (Bx) / Refractive Index (RI)
Measuring range: 0 ‐ 95 Bx / 1.33 ‐ 1.54 RI
Resolution: 0.1 Bx / 0.0001 RI
Accuracy: ± 0.2 Bx / ± 0.0003 RI |
DHR Honey |
Measuring scales: Sugar % (Bx) / Water in Honey (%)
Measuring range: 0 ‐ 95 Bx / 10 - 30 %
Resolution: 0.1 Bx / 0.1 %
Accuracy: ± 0.2 Bx / ± 0.2 % |
DHR Wine |
Measuring scales: % Mass w/w (%) / Alcohol Probable (AP)
Measuring range: 0 ‐ 35 % / 0 - 22 AP
Resolution: 0.1 % / 0.1 AP
Accuracy: ± 0.2 % / ± 0.2 AP |
DHR Oe |
Measuring scales: % Mass w/w (%) / ° Oechsle (°)
Measuring range: 0 ‐ 35 % / 30 - 130 °
Resolution: 0.1 % / 1 °
Accuracy: ± 0.2 % / ± 1 ° |
DHR Saline |
Measuring scales: Sugar % (Bx) / Saline (NaCl)
Measuring range: 0 ‐ 54 Bx / 0 - 28 NaCl
Resolution: 0.1 Bx / 0.1 NaCl
Accuracy: ± 0.2 Bx / ± 0.2 NaCl |
DHR Aqua |
Measuring scales: Seawater PPT (Part Per Thousand) / Seawater Specific Gravity (SG)
Measuring range: 0 ‐ 180 Part Per Thousand / 1.000 ‐ 1.070 SG
Resolution: 1 Part Per Thousand / 0.0005 SG
Accuracy: ± 1 Part Per Thousand / ± 0.001 SG |
DHR Vet |
Measuring scales: Urine Specific Gravity (SG) small mammal / Urine Specific Gravity (SG) large mammal
Measuring range: 1.000 ‐ 1.050 SG / 1.000 ‐ 1.050 SG
Resolution: 0.0005 SG / 0.0001 SG
Accuracy: ± 0.001 SG / ± 0.001 SG |
DHR PG |
Measuring scales: Propylene Glycol % by volume (%) / Propylene Glycol °C Protection (°C)
Measuring range: 0 ‐ 60 % / 0 to ‐ 50 °C
Resolution: 0.1 % / 1 °C
Accuracy: ± 0.4 % / ± 1 °C |
DHR EG |
Measuring scales: Ethylene Glycol % by volume (%) / Ethylene Glycol °C Protection (°C)
Measuring range: 0 ‐ 60 % / 0 to ‐ 50 °C
Resolution: 0.1 % / 1 °C
Accuracy: ± 0.4 % / ± 1 °C |
DHR DEF |
Measuring scales: Sugar % (Bx) / For measuring AdBlue©
Measuring range: 0 ‐ 54 Bx / 0 - 40
Resolution: 0.1 Bx / 0.1
Accuracy: ± 0.2 Bx / ± 0.2 |
Công ty CP Công Nghệ Đỉnh Cao
Trụ sở: Số 12 Chân Cầm, Hàng Trống, Hoàn Kiếm, Hà nội
VPGD: Phòng E2, Tòa nhà C4, Đường Đỗ Nhuận, Xuân Đỉnh, Từ Liêm, Hà nội
Tel: +84 (4) 22428148; Cel: 0984843683,Fax: +84 (4) 37505143
VPGD: Tầng 19, Tòa nhà Indochina/ Số 4, Nguyễn Đình Chiểu, P.Đakao, Q.1,
TP Hồ Chí Minh..
Tel: 08.6685 8911 Fax: 08.6284 0993.
Website: www.ttech.vn, www.store.ttech.vn, www.tshops.vn, www.stock.ttech.vn, http://www.omega-air.vn/