ImageMaster® Universal - MTF Testing in the Spectral Range UV-VIS-NIR-SWIR-MWIR-LWIR

Mã sản phẩm: ImageMaster® Universal |
Thương hiệu: Trioptics

Giá bán: Liên hệ

The ImageMaster® Universal Series has been specifically developed to cover the MTF measurement of a large set of optical parameters over a wide spectral range. Virtually any existing lens system ranging from high performance photographic imaging lenses to high resolution telescopes can be accurately measured in: IR, Visible, UV.

Yêu Cầu Giá Tốt

Thông tin sản phẩm

Key Features


  • Image quality evaluation of any existing lens system: infinite, finite, afocal
  • Measurement of the modulation transfer function (MTF) off-axis and on axis
  • Modular and upgradable design
  • Quick exchange of different modules within a few minutes (e.g. changing from VIS to IR)
  • MTF values tracable to international standards
  • Perfectly aligned measurement heads using proprietary alignment procedures
  • Cover for diffraction limited collimators to avoid ambient light and air turbulences
  • Innovative and time saving IR area sensor method
  • Years of experiences and from a high diversity of customers


Applications

Parameter ImageMaster® Universal
Optical set up Finite, infinite or afocal
Max. off-axis angle ± 135
Spectral range UV: 250nm … 400nm
VIS: 400nm … 700nm
NIR: 700nm … 1000nm
SWIR: 1000nm … 1700nm
MWIR: 3µm … 5µm
LWIR: 7µm … 13µm
Azimuth range 360°
Max. image height ± 50mm
Spatial frequency (in specification)
Max. spatial frequency
200 lp/mm in UV
500 lp/mm in VIS / NIR
150 lp/mm in SWIR
100 lp/mm in MWIR
60 lp/mm in LWIR
Accuracy MTF on-axis and off-axis ±0.02MTF on axis
Repeatability ±0.01MTF
EFL 
Accuracy 

±0.2%
Distortion 
Accuracy (without / with encoder)
Repeatability (without / with encoder)

± 0.7% / ± 0.25%
± 0.3% / ± 0.1%
Lateral chromatic aberration 
Accuracy
Repeatability

± 0.5 µm
± 0.3 µm
Longitudinal chromatic aberration
Accuracy
Repeatability

± 1 µm
0.2 µm
CRA
Accuracy
Repeatability

± 1°
± 0.4°
FFL (relative)
Accuracy
Repeatability

± 2 µm
± 1 µm
Astigmatism
Accuracy
Repeatability

± 4 µm
± 1 µm
Field curvature
Accuracy
Repeatability

± 2 µm
± 1 µm

All MTF measurements can be accomplished in finite, infinite and afocal measurement position

  • Modulation transfer function on axis and off axis
  • Through Focus MTF
  • Line Spread Function
  • Phase Transfer Function
  • Effective Focal Length
  • FFL/BFL (relative)
  • Distortion
  • Astigmatism
  • Field Curvature
  • etc.



SẢN PHẨM CÙNG DANH MỤC