The installation allows testing:
    - Rubber dielectric gloves;
- Rubber dielectric boots;
- Insulating materials on the DIY instruments (screw drivers, cutting pliers, etc.).
Equipment included in the SVS-50C package could be used for testing insulators with AC current (cable sheath, etc.).
    - Technical Specifications
 - 
    - General SVS-50C specifications: 
 
 
- Operating Conditions
 
    The device is designed for an indoors operation under the following conditions: 
     
        
            
                | Condition | Value |  
                | Air temperature, °С | from +10 to +35 
 |  
                | Relative humidity, %, up to 
 | 80 at +20 °С |  
                | Atmospheric pressure, kPa (mm hg) 
 | 84,0 – 106,7 (630 – 800) |  
 
 
    
        
            | Characteristic | Value | 
        
            | Single-phase AC power supply voltage, V | 220±22 | 
        
            | Power supply frequency, Hz | 50±2 | 
        
            | Reduced error of voltage measurements in the range from 20 to 100 V, % | ±3 | 
        
            | Reduced error of voltage measurements in the range from 1 to 6.5 kV, % | ±3 | 
        
            | Reduced error of voltage measurements in the range from 6.5 to 15 kV, % | ±3 | 
        
            | Reduced error of voltage measurements in the range from 10 to 50 kV, % | ±3 | 
        
            | Reduced error of current measurements, % | ±3 | 
        
            | Maximum consumed power, kW | 0,9 | 
        
            | Lifespan, years, avg | 10 | 
    
 
Test basin specifications:
    
        
            | Characteristic | Value | 
        
            | Maximum voltage, kV 
 | 15 | 
        
            | Range of measurements of leakage currents, mA | 0.3-7.5 | 
        
            | Number of spaces of test subjects | 4 | 
        
            | Dimensions, mm, max | 700х795х865 | 
        
            | Net weight in dry condition, kg, max | 30 | 
    
 
Control unit specifications:
    
        
            | Characteristic | Value | 
        
            | Consumed power, W, max 
 | 20 | 
        
            | Dimensions, mm, max | 316х187х132 | 
        
            | Net weight, kg, max | 3 | 
    
 
Measuring unit specifications:
    
        
            | Characteristic 
 | Value 
 | 
        
            | Power consumption measuring unit + BVI, VA, max | 2000 | 
        
            | Dimensions, mm, max 
 | 330х500х380 
 | 
        
            | Net weight, kg, max | 27 | 
    
 
High voltage unit BVI-50 specifications:
    
        
            | Characteristic | Value | 
        
            | Range of leakage current measurements, mA 
 | 0.3...10.0 | 
        
            | Maximum voltage, kV 
 | 50 | 
        
            | Dimensions, mm, max | 270×230×370 | 
        