| Accuracy assured flow-rate range *2 | 0.05~1 L/min | 0.5~10 L/min | 3.0~60L/min | 
        
            | Measurement starting flow-rate | 0.025 L/min | 0.25 L/min | 1.5 L/min | 
        
            | Piping connection | Socket type union joint (16A)
 | Socket type union joint (16A)
 | Socket type union joint (20A)
 | 
        
            | Accuracy *3 | Unit pulse output | ±2.0%RS (100~20% of the maximum flow-rate) ±0.4%FS (20~5% of the maximum flow-rate)
 | 
        
            | Response time (at 63% response) | Standard: 2 seconds. Setting within the range of 0.1600 seconds is available. | 
        
            | Fluid temperature range | 0~40°C, freezing must be avoided. (VNS05 can resist 15 minutes per day of 95°C, whereas its accuracy is out of guarantee. | 
        
            | Measurable fluid | 
                Sodium hypochlorite (Concentration of 1~12%)Sodium hydroxide aqueous solution (Concentration of 10~25%) For other kind of liquid, by selecting with reference to the following major materials of the fluid-touching materials, please consult with us for suitability confirmation. | 
        
            | Working ambient temperature range | -20~60°C | 
        
            | Ambient temperature range for storage | -20~70°C | 
        
            | Fluid pressure range | 0~1MPa | 
        
            | Signal cable | 
                Standard cable length 0.5m4-wires (AWG26)Line 1: Power + line
 Line 2: Power – line
 Line 3: Output 1
 Line 4: Output 2
Top of the each: Soldered stranded wire | 
        
            | Display | 1 LED display at the flowsensor’s body 
                Green: Flow-rate indication (Indication with blinking speed of 3 steps)Red: Alarm indication (Indication of abnormality with numbers of blinking) | 
        
            | Place of installation | Indoor installation (In case of outdoor installation, please take necessary measure so that the flowsensor is not exposed to rain and sun beam directly.)
 | 
        
            | Enclosure | IPX4 | 
        
            | Corresponding standard | CE Standard *1 | 
        
            | Fluid-touching materials | Main body: PEEK resin Electrodes: Pure titanium (2 kinds)O-ring: For sodium hypochlorite, etc. – FKM (Fluoro rubber)
 For Sodium hydroxide aqueous solution, etc. — EPDM (Ethylene propylene rubber)
 | 
        
            | Installation position | Free (Vertical piping is recommended.) |