Compliance HT-2800PR Hipot Tester, 0-2800Vdc 5mA, Adjustable Ground Continuity

Mã sản phẩm: |
Thương hiệu: Compliance

Giá bán: Liên hệ
Tester The New product of our Hipot Line Tester, the HT-PR series Hipot Tester now with adjustable ground continuity test in range of 0.08 Ω - 1.50 Ω, Auto-offset for test leads up to 1.00 Ω, Performs 0-2800 DC Hipot Test. Neutral/Hot to Ground Leakage current test up to 5 mA DC. Easy to use and connect, Ships complete with cables, a manual, and a Calibration Certificate. Made in the USA. Calibration and repair services available.

Yêu Cầu Giá Tốt

Thông tin sản phẩm

Feature:

High precision leakage current, duration and ground continuity settings
Allows no load setup of leakage current and test dwell times
Once entered, ground continuity setting, leakage current and test dwell times can be referenced on the front panel display when unit is not testing
Leakage currents can be set from 1-5 mA DC in 0.1mA increments
Dwell times can be set from 1-60 seconds in 1 second increments
Two tests with one setup. Conducts UL/CSA Ground continuity and Hipot tests with one setup, so no additional equipment is needed
Small and light. 9.25" wide x 4.75" high x 10" deep. 14 lbs. But rugged enough to test manufactured housing
Ground continuity check is defeatable for testing two-wire products
Easy equipment connections. Plug your equipment right into the NEMA plug on the front panel. No adapters needed!
J2 and J3 cords allow connection of pigtail power leads
Simple test outcome judgement. Green lights mean pass - red lights mean fail. Failing tests sound a buzzer as well
Ready for your UL Inspector out of the box. NIST Traceable Calibration Certificate to MIL-STD45662-A is included. Cal cert is in accordance with UL guidance
Operation Instructions are printed on the rear panel for easy reference
In-depth testing. Both true Arc Dectection and Leakage Current circuits test the product to find problems
RED lights and a buzzer leave no question if a failure has occurred
Expandable for TUV/European Agency Testing. Can be connected to our GF-30ac 25A Ground Bond Tester with optional TEST-LINK™
Easy shift-by-shift Function Test. Compatible with our Patented function checker, the HTT-1and HTT-1R (With 0.1 ohm Ground check Pass/Fail Setup)


General Specifications
Voltage Test Type AC/DC
Voltage Range 0-2000 AC  0-2800 DC
Leakage Current Set Point 1-20  mA AC   1-5 mA DC
Input Voltage Requirements 117-127 V, 50 /60 Hz
Fuse Requirements 120 V, 2 A Slow Blow
Arc Detect Independent High Frequency  Circuit
Leakage Detect Independent Low Frequency Circuit 
Ground Continuity Set Point 0.08-1.5 Ω, Defeatable
Ground Continuity Test Current 100 mA
Test Time Range 1 - 60 Seconds
Ramp Time Range 1 - 5 Seconds
Voltage Meter Accuracy ± 2 %

HV Shutdown by Ground Fail

<  7 mS

Duty Cycle 100%

Discharge Time

 

< 7 mS VAC

< 1.3 Sec VDC at open circuit

Transformer Power < 500 VAC
Pass/Fail Repeatability ± 3 %

Output Connector

 

NEMA plug, Alligator Clip (HT-3000PR only)

Display 4 digits LED display
Test Indicator Led indicators
Failure Indicator Led indicators and buzzer
Programable No
PLC Interface Optional
TestLink (With GF-30AC) Optional
Computer Control No
Voltage Hold on failure No
Top Mounted Handle Optional
Test Defeat Ground Continuity
Autoreset on Pass Optional
Operation Temperature 15 - 40 °C
Relative Humidity Range 0 - 90 % Non-condensing
Dimensions 9-1/4" wide x 4-3/4" high x 10" deep
Weight 14 Lbs
Calibration One year calibration Certificate

Test Cords

 

 

 

Return Lead, Power Cord

Ground Continuity Connector Tip

J2 and J3 Optional

Alligator Clip (HT-3000PR Only)


SẢN PHẨM CÙNG DANH MỤC