Features
 Semi-micro, 0.01 mg resolution up to 42 g (GR-202)
 Handy lever on the front to open either side of the weighing chamber for quick and efficient access
 Small footprint of 249 mm by 330 mm to save space
 Adjustable (manual or automatic) response characteristics to help cope with the effect of drafts and vibrations
 Automatic self calibration to maintain accuracy under temperature changes
 Anti-static glass breeze break with a thin evaporated metal coating
 Multiple weighing units: g, mg, oz, ozt, ct, mom, dwt, grain, specific gravity (either tael or tola can be added upon request)
 GLP/GMP/GCP/ISO compliant output
 Data memory function
 Counting mode with the Automatic Counting Accuracy Improvement (ACAI) function
 Percent mode function
 Auto power on function
 Underhook function
 Density determination function and an optional density determination kit
 Windows Communication Tools software (WinCT) on CD-ROM
 
Specifications
    
        
            | 
             Model 
             | 
            
             GR-202 
             | 
            
             GR-120 
             | 
            
             GR-200 
             | 
            
             GR-300 
             | 
        
        
            | 
             Weighing capacity 
             | 
            
             42 g/210 g 
             | 
            
             120 g 
             | 
            
             210 g 
             | 
            
             310 g 
             | 
        
        
            | 
             Minimum weighing value 
             | 
            
             0.01 mg/0.1 mg 
             | 
            
             0.1 mg 
             | 
        
        
            | 
             Repeatability (Standard deviation) 
             | 
            
             0.02 mg/0.1 mg 
             | 
            
             0.1 mg 
             | 
            
             0.2 mg 
             | 
        
        
            | 
             Linearity 
             | 
            
             ±0.03 mg /±0.2 mg 
             | 
            
             ±0.2 mg 
             | 
            
             ±0.3 mg 
             | 
        
        
            | 
             Sensitivity drift (10 °C to 30 °C) 
             | 
            
             ±2 ppm/˚C (when automatic self calibration is not used) 
             | 
        
        
            | 
             Weighing pan 
             | 
            
             Ø85 mm 
              
             |