Withstanding Voltage |
AC 5500V, 1 minute (between operation handle and core of CT) |
Storage Temperature |
-10℃ - 60℃, less than 70%RH (Without condensation) |
Accuracy |
23℃±5℃ 80%RH or less (50/60Hz)
Range/Resolution/Accuracy(50/60Hz)
AC 30A/0.01A/±1.5%rdg±8dgt
AC 300A/0.1A/±1.5%rdg±8dgt
AC 3000A/1A/±2.0%rdg±8dgt |
Operating Temperature |
0℃ - 40℃, less than 80%RH (Without condensation) |
Power supply |
1.5V battery[UM-4 or AAA size]x 2 |
Power consumption |
Approx. 6mW |
Measuring Range |
AC30A/300A/3000A (50/60Hz)
3 ranges manual |
AC Conversion |
AC coupled true rms responding |
Safety standard |
IEC61010-1, IEC61010-2-032
Installation Category.
CategoryⅢ600V |
Limitation of circuit voltage |
Less than AC 600V |
Accessories |
Battery (UM-4):2
Instruction Manual:1
Carrying Case:1
Hand Strap:1 |
Display |
LCD, max. 3200 count with annunciators |
Dimension and weight |
194(W) x 341.5(H) x 52(D) mm, Approx. 1.8kgs |
Measuring function |
AC load current |
Over range indication |
"OL" mark on LCD |
Data hold indication |
"DH" mark on LCD |
Low battery indication |
"Battery" mark on LCD |
Measuring method |
Dual slope integration mode |
Battery life |
Approx. 200 hours continuous |
Sampling |
2 times/sec |
Auto power off function |
The meter is set to power off Approx. 10 minute later after power on. |
Max Jaw Opening capability |
108mm (108x128mm) |