Sampling |
2 times/sec |
Polarity |
"-" sign for negative polarity |
Withstanding Voltage |
AC 3700V 1 minute max. (Between the core of CT and outer case) |
Storage Temperature |
-10℃ to 60℃, 70%RH max. ( Without condensation ) |
Accuracy |
(23℃±5℃, 80%RH or less)
Range/Input range/Accuracy
AC 200A/0~199.9A/±1.5% rdg±5 dgt(50/60Hz)
AC1000A/0~1000A/±1.5% rdg±5 dgt(50/60Hz)
DC 200A/0~199.9A/±1.5% rdg±5 dgt
DC1000A/0~1000A/±1.5% rdg±5 dgt |
Operating Temperature |
0℃ to 40℃, 80%RH max. ( Without condensation ) |
Power supply |
1.55V (SR-44, LR-44)×2 |
Power consumption |
7mW |
Weight |
Approx. 170g |
Safety standard |
IEC 61010-1, IEC 61010-2-032
Installation CategoryⅡ600V or CategoryⅢ300V. |
Jaw opening capability |
40mmφ |
Size |
68.5(W)×175(H)×23(D)mm |
Accessories |
Soft case:1
Instruction manual:1
Batteries LR-44(1.55V):2 |
Display |
3.5 digit LCD, max. reading of 1999 |
Over range indication |
Blanking of all digits except MSD 1 |
Data hold indication |
"DH" mark on LCD |
Low battery indication |
"B" mark on LCD |
E.M.C. standard |
EN 61326 |
Measuring method |
Dual slope integration mode |
Battery life |
SR-44 (30 hours), LR-44 (16 hours) |
Range |
AC/DC 0~200A/1000A, 2 ranges manual |
Maximum indication |
1999 |