2 Ch. Thermocouple Data Logger with display KTT220O Sauermann

Mã sản phẩm: KTT220O |
Thương hiệu: Sauermann

Giá bán: Liên hệ
The versatility of class 220 comes from the extensive measure- ment parameters offering a broad range of applications. Thanks to the additional input for the connection of interchangeable sensors, the devices can simultaneously record up to 5 measuring channels.


Yêu Cầu Giá Tốt

Thông tin sản phẩm
Features

KTT220O 2 Ch. Thermocouple Data Logger with display
Record up to 5 parameters simultaneously
Monitoring mode for detailed reporting outside of set points
Large storage capacity of 1 million points
Fast data downloading (18,000 points/second)
Magnetic back for fast & simple mounting
Large easy to read 2-line display
2 configurable set points alarms for each channel
Free, downloadable basic software


Model KT 220 KH 220 KH 220
Units displayed °F, °C, °Ctd, °Ftd, %RH, mV, V, mA, A, bar 1 °F, °C, °Ctd, °Ftd, %RH, lux, fc, mV, V, mA, A, bar 1 °F, °C
Resolution 0.1°F, 0.1°C, 0.1%RH, 1 mV, 0.00 V,
0.001mA, 0.1 A, 0.1 bar
0.1°F, 0.1°C, 0.1%RH, 1 lux, 0.1 fc, 1 mV
0.001 V, 0.001 mA, 0.1 A, 0.1 bar
0.1°F, 0,1°C
External input Female micro-USB connector Female micro-USB connector Female micro-USB connector
Input for probe 1 universal input 1 universal input 2 inputs for thermocouple probes (K, J, T, N, S)
Internal sensor Temperature Temperature, humidity, light Temperature
Type of sensor Thermistor (NTC) Thermistor (NTC), capacitive, photodiode Thermocouple
Measuring range Internal sensor 3 :
-40 to 158°F
(-40 to 70°C)
Internal sensor 3 :
Temp.: -4 to 158°F (-20 to 70°C)
Humidity: 0 to 100%RH
Light: 0 to 10,000 lux
K: -328 to 2372°F (-200 to 1300°C)
J: -148 to 1382°F (-100 to 750°C)
T: -328 to 752°F (-200 to 400°C)
N: -328 to 2372°F (-200 to 1300°C)
S: 32 to 3200°F (0 to 1760°C)
Accuracies ±0.8°F from -4 to 158°F
(±0.4°C from -20 to 70°C)

±1.5°F below -4°F
(±0.8°C below -20°C)
Temp: ±0.8°F from 32 to 122°F
(±0.4°C from 0 to 50°C)
±1.5°F below 32°F or above 122°F
(±0.8°C below 0°C or above 50°C)

Humidity 5 : ±2%RH from 5 to 95%RH @ 59 to 77°F
(15°C to 25°C)

Light: ±10% of reading 10 lux
K, J, T, N: ±0.8°F from 32 to 2372°F
(±0.4°C from 0 to 1300°C)
±(0.3% of the reading 0.8°F) below 32°F
(±(0.3 % of the reading 0.4°C) below 0°C)

S: ±1.1°F (±0.6°C)
Operating temperature -40 to 158°F (-40 to 70°C) -4 to 158°F (-20 to 70°C) -4 to 158°F (-20 to 70°C)
Storage temperature -40 to 185°F (-40 to 85°C) -40 to 185°F (-40 to 85°C) -40 to 185°F (-40 to 85°C)
Alarm set points 2 alarm set points per channel 2 alarm set points per channel 2 alarm set points per channel
Frequency of measurement 1 s to 24 h 1 s to 24 h 1 s to 24 h
Battery life 4 years 4 years 4 years
Warranty 1 year 1 year 1 year
Directives 2011/65/EU RoHS II; 2012/19/EU WEEE; FCC part 15; UL 61010