| Measurement principle | 
            Inductive | 
        
        
            | Medium | 
            non-aggressive gases | 
        
        
            | Wetted parts | 
            Ni, Al, CuBe, PU | 
        
        
            | Linearity | 
            0.2% FS | 
        
        
            | Hysteresis | 
            0.1% max. FS | 
        
        
            | Long term stability | 
            ±0.5% per year (typical) | 
        
        
            | Sensor volume | 
            approx. 3 ml | 
        
        
            | Volume increase | 
            approx. 0.2 ml at nominal pressure | 
        
        
            | Pump | 
            variable displacement volume | 
        
        
            | Bellows (fine adjustment) | 
            Displacement volume approx. 25 cm² at 20 crankshaft rotations | 
        
        
            | Power supply | 
            9 V E-Block battery or mains power adapter 230 VAC 50/60 Hz | 
        
        
            | Current consumption | 
            Est 10 mA | 
        
        
            | Protection | 
            250 eye | 
        
        
            | Supply influence | 
            <0.05% | 
        
        
            | Option | 
            Analogue output 0...1 V (max. load resistance >=2 KOhm) | 
        
        
            | Display | 
            LCD 3 1/2 digits (12.5 mm); Option: LCD 4 1/2 digits (12.5 mm) | 
        
        
            | Response time | 
            Adjustable 0.3 / 1 / 2 seconds | 
        
        
            | Pressure connections | 
            for flexible hoses with inner diameter 6 mm | 
        
        
            | Electrical connections | 
            Power supply jack plugs for plug-in power supply; 4 mm banana plugs for optional analogue output | 
        
        
            | Temperature influence | 
            Zeropoint ±0.03% v.E. / K; span ±0.03% v.E. / K | 
        
        
            | Temperaturbe ranges | 
            specified range from +10C to +40°C | 
        
        
            | Humidity | 
            up to 80% relative humidity | 
        
        
            | Storage temperature | 
            -10 ° C ... + 70 ° C | 
        
        
            | Housing | 
            Bench housing in aluminium 248 x 225 x 90 mm | 
        
        
            | Shock resistance | 
            1 g | 
        
        
            | Housing colour | 
            Grey, front green anodized | 
        
        
            | Protection class | 
            III | 
        
        
            | Degree of protection | 
            IP 30 | 
        
        
            | Applie norms | 
            EN 50081-1; EN 50081-2; EN 50082-1; EN 50082-2; EN 61010 | 
        
        
            | Weight | 
            approx. 2 kg |