THERMO-COLLECTOR TM20 (DOUBLE FUNCTION) Yokogawa

Mã sản phẩm: TM20 |
Thương hiệu: Yokogawa

Giá bán: Liên hệ
The TM20 offers excellent data management functions:


Collect up to 5000 data items with time-stamp, tag name and inspector name.
Save 2 weeks continuous data logging with 1 minute interval (up to 20000 data items, measuring interval is 1sec. to 24 hours.).
Information on when, by whom and what is measured is saved along with the data.

Thông tin sản phẩm
Model Universal dual inputs
No. of Measuring Channels 2 (when A and B channels are used for thermocouple or voltage input)
1 (when D channel is used with the non-contact probe)
Measuring Range Thermal emission -20ºC to 400ºC (-4ºF to 752ºF)
Type K: -200ºC to 1372ºC (-328ºF to 2501.6ºF)
Type J: -200ºC to 1000ºC (-328ºF to 1832ºF)
Type E: -200ºC to 700ºC (-328ºF to 1292ºF)
Type T: -200ºC to 400ºC (-328ºF to 752ºF)
Voltage input ± 100 mV, ± 1 V
Resolution Thermocouple: 0.1°C
Thermal Emission: 1°C
Voltage Input: 0.1 mV or 0.001 V
Accuracy Thermocouple: -200.0 to 100.1°C: ±(0.1% of rdg + 0.7°C)
-100.0°C or above: ±(0.1% of rdg + 1.0°C)
Accuracy of reference junction compensation is included ±0.4°C when the temperature of the input terminal is in equilibrium.
Thermal emission ±(1% of rdg + 1°C) or ±3°C, depending on the accuracy of the non-contact probe.
Voltage Input ±(0.1% of rdg + 0.2% of range)
Measuring Mode Collector
Logging
Measuring Interval Collector Mode: 0.5 seconds or longer when 1 channel is used.
1 second or longer when 2 channels are used.
Logging Mode: 1 second to 24 hours when 1 channel is used.
2 seconds to 24 hours when 2 channels are used.
Data Capacity 5000 data items when used in collector mode only.
20000 data items when used in logging mode only.
Measurement data obtained in collector mode and logging mode can coexist.
Under simultaneous 2-channel measurement, 2 data items are recorded at th
Drip-proof Construction Conforms to IP54 standards (dust-proof and drip-proof requirements of IEC529)
Display LCD with backlight
Operating Temperature 0 to 50 ºC
Humidity 20 to 80% RH (no condensation)
Power Requirements Two AA-size alkaline dry batteries (LR6)
Battery Life Approx. 1.5 months when operated in logging mode at 10-minute intervals;
Approx. 1 month when operated in logging mode at 1-minute intervals;
Approx. 5 days when operated in collector mode 8 hours a day including 30 minutes of communication.
Registration of Tag Names A maximum of 50, each comprising up to 8 alphanumeric characters
Registration of Operator Names A maximum of 10, each comprising up to 8 alphanumeric characters
Registration of Comments A maximum of 32, each comprising up to 8 alphanumeric characters
Alarm Function Upper- and lower-limit alarms
Computing Function Maximum, minimum, and average
Reading of difference between the 2 channels is possible.
Communication Function Conforms to EIA RS-232C standard.
Simplified Correction Function Corrects the measured data from thermocouple input within the range of ± 20.0ºC.
Scaling function Scales the voltage input x according to the formula “Ax + B,” which is defined from the thermo-collector software.
Other Functions Chime, function lock, clock display, auto power-off, and battery alarm
Thermo-collector Software System Requirements CPU: i486DX or higher Recommended memory capacity: 16 MB or greater
OS: Windows 95/Windows 98/Windows NT 4.0 Serial I/O capability: A serial port conforming to RS-232C standard should be available.
FDD: 3.5", 1.44 MB-formatted Software: Microsoft Excel 95, Microsoft Excel 97
Required space on the HDD: 10 MB or greater  
Compliance with Standards EMC Standards 
EMI (interference signal): EN55011;1998, EN61326-1;1998+A1 (Class B, Group 1)
EMS (immunity): EN50082-1;1997, EN61326;1998+A1