Parameter |
Value |
Basic set
|
Carrying case with: electrostatic discharge simulator, battery pack, battery charger 100 to 240 VAC, discharge network 150 pF/330 Ω, air- and contact-discharge tips, grounding cable, tripod adapter, user manual
|
Pulse
network
|
Network 150 pF/330 Ω as per IEC/EN 61000-4-2 (included)
Range of R/C networks for other standards: R = 0 Ω to 10 kΩ; C = 60 to 500 pF
|
Discharge voltage
|
Air-discharge: 200 V to 16.5 kV (in 100 V steps)
Contact-discharge: 200 V to 9 kV (in 100 V steps)
|
Discharge
tips
|
Ball and point as per IEC
|
Charging voltage measurement
|
kV, accuracy better than ±5% (stabilized); measurement and display of true air flashover voltage
|
Discharge detection
|
Indicated by an oval around the kV symbol, also acoustically in the 'Single' operating mode (air-discharge only)
|
Holding time
|
>5 s (charging voltage ... ±5%)
|
Polarity
|
Positive / negative / automatic change
|
Operating modes
|
Single / repetitive =
pulse counter: 0 to 9999, preselect counter 0 to 9999
Repetition: 0.5/1/5/10/20 or 25 Hz (air); 0.5/1/5 or 10 Hz (contact);
continuous operation
|
Display
|
LCD panel showing: charging voltage, discharge voltage, polarity, air-/contact-discharge, counter/preselect counter content, soft-key functions, battery monitor
|
Weight
|
NSG 435 with battery: 1.2 kg (2.6 lbs) approx.
|
Ambient conditions
|
Operation: +5 to +40°C, 20 to 80 % r.h. (non-condensing), 68 to 106 kPa
|