Display (LCD, Digital Counts) |
3999 |
AC Current Accuracy (400A Reference) |
1.0+3(50/60Hz)
2.0+3(40~1kHz) |
AC Current Accuracy (2000A Reference, 0~1500A) |
1.0+3(50/60Hz)
3.0+3(40~1kHz) |
AC Voltage Accuracy (40/400V/750V Reference) |
1.0+2(50/60Hz)
1.5+3(40~1kHz) |
DC Voltage Accuracy (40/400V/1000V Reference) |
1.0+2 |
Resistance Accuracy (400/4k/40k/400kΩ reference) |
1.5+2, Beeps at below 50± 35Ω (continuity check) |
DC Output Accuracy (400A, 0~400mV Reference) |
.5۫% rdg ± 0.5mV (50/60Hz)
.5% rdg ± 0.5mV (40~1kHz) |
Method of detection |
Mean Value |
Response Time |
Approx. 2 seconds |
Range Switching |
Manual-range (on AC current range) / Auto-range (on AC voltage range, resistance range) |
Data hold |
On all range |
Operating temperature and humidity |
0-40°C, 85% RH or less (no condensation) |
Influence of external magnetic field |
1A or less at 400A/m |
Influence of conductor position |
± (2% rdg + 3dgt) or less |
Safety Standard |
Conforms EN 61010-1, EN61010-2-031, EN61010-2-032 |
Circuit voltage |
1000Vrms or less |
Withstanding voltage |
5.55kV AC for one minute |
Power Supply |
R6P(SUM-3)x2 or LR6x2 |
Battery Life1 |
150 hours |
Consumed current |
Approx. 5mA |
Sleep Function |
Automatically powered down in about 10 minutes after the last switch operation |
Diameter of measurable conductor |
54mm at maximum |
Dimensions |
Approx. 105(W) x 247(H) x 49(D)mm |
Weight (Approx.) |
470g |
Accessories |
Clamp Adapter (Model 99025), Output Cable for Terminal Screw (Model 91019), Carrying Case (Model 93034), Output Plug (Model 98012), Test Lead (Model 98011), User's manual (IM CL150), batteries |
Order Notes |
Each item selected MUST be ordered as a separate line item. |
Product Notes |
All Clamp-on Meters include Test Leads (where applicable) and a carrying case. |